Sale!

NI PXI-4472B | 8-Channel 24-Bit Dynamic Signal Acquisition Module

Original price was: ¥999.00.Current price is: ¥888.00.

NI PXI-4472B | 8-Channel 24-Bit Dynamic Signal Acquisition Module

  • Exact Model: PXI-4472B (Part Numbers: 779339-01, 192892B-01)
  • OEM Brand: National Instruments (NI)
  • System Series: PXI Modular Instrumentation / Sound and Vibration Architecture
  • Core Function: Acquires high-fidelity AC/DC voltage, acoustic, and vibration signals simultaneously across 8 channels with integrated IEPE sensor conditioning.
  • Module Type: 8-Channel 24-Bit Dynamic Signal Acquisition (DSA) Module
  • Defining Specs: 102.4 kS/s simultaneous sampling rate per channel, 24-bit Delta-Sigma ADCs, 110 dB dynamic range, built-in AC/DC coupling and 4 mA IEPE sensor power.
Category:

Description

NI PXI-4472B | 8-Channel 24-Bit Dynamic Signal Acquisition Module

 

Dynamic Product Introduction

Acoustic testing, rotating machinery vibration analysis, and structural modal testing require high-resolution analog-to-digital conversion capable of capturing subtle dynamic signals without phase distortion or aliasing noise. Traditional data acquisition cards often suffer from channel-to-channel phase skew and limited dynamic range when measuring low-level accelerometer or microphone feeds. The National Instruments PXI-4472B dynamic signal acquisition module addresses these demands by providing 8 simultaneously sampled channels equipped with 24-bit Delta-Sigma converters and software-selectable anti-aliasing filters.

Engineered specifically for precision sound and vibration measurements, the PXI-4472B delivers a wide 110 dB dynamic range and supports built-in 4 mA constant current excitation (IEPE) for direct connection to ICP sensors. (Honestly, having onboard anti-aliasing filters that automatically adjust to your selected sampling rate eliminates signal aliasing errors without requiring external conditioning boxes.) Featuring tight multi-module synchronization over the PXI trigger bus, the PXI-4472B remains a cornerstone for modal analysis and noise-abatement testing—though long-term measurement accuracy depends entirely on maintaining calibrated analog input front-ends.

PXI-4472B

PXI-4472B

Key Technical Specifications

  • Manufacturer & System Platform: National Instruments (NI) / PXI Sound and Vibration Series
  • Module Part Number: PXI-4472B / 779339-01 / 192892B-01
  • Number of Input Channels: 8 simultaneously sampled analog input channels
  • ADC Resolution: 24-bit Delta-Sigma ADCs with oversampling
  • Maximum Sampling Rate: 102.4 kS/s per channel (software selectable down to 1.61 kS/s)
  • Dynamic Range: 110 dB typical (10 Hz to 45 kHz bandwidth)
  • Sensor Excitation: Built-in 4 mA IEPE (ICP) current source per channel (switchable on/off)
  • Input Coupling & Range: AC or DC coupling; software-selectable voltage input ranges (\pm 1 V to \pm 10 V)
  • Front Panel Connectors: 8 BNC female input connectors
  • Operating Ambient Temperature: 0°C to +55°C (32°F to 131°F) continuous operational envelope
  • Dimensions & Weight: Standard 3U PXI single-slot module, approximately 0.35 kg (0.77 lbs)

 

Global Sourcing & Live-Test SOP (Transparency Core)

Procuring secondary-market or surplus precision instrumentation requires exhaustive electrical calibration and signal integrity verification before deployment in test laboratories. Every NI PXI-4472B module entering our inventory undergoes a rigorous five-stage bench qualification process:

  • Inbound Visual & BNC Inspection: Serial numbers and PCB revision stamps are cross-referenced against NI manufacturing databases. We inspect all 8 front-panel BNC connectors for stripped threads or bent center pins, and examine the board edge connector for gold-plating wear.
  • Live PXI Rack Simulation: The PXI-4472B module is inserted into an NI PXI-1033 or PXIe-1082 test chassis connected to a development PC running NI-DAQmx and LabVIEW.
  • Frequency Response & Calibration Sweep: Using a precision audio analyzer (such as an Audio Precision APx555) connected via BNC cables, we inject known sinusoidal AC signals across all 8 channels. We measure amplitude flatness, harmonic distortion (THD+N), and dynamic range across the 102.4 kS/s sampling spectrum.
  • IEPE Excitation & Coupling Test: The internal 4 mA constant current source is enabled for each channel to verify proper voltage compliance and DC bias stabilization for attached ICP accelerometers.
  • Final Prep: Non-volatile calibration registers are verified against baseline specs, protective BNC caps are installed, and the PXI-4472B module is sealed inside heavy-duty anti-static moisture-barrier packaging.

 

The Field Engineer’s Pitfall Guide

❗ Exceeding Maximum Common-Mode Voltage Limits on BNC Inputs: Never apply common-mode voltages exceeding the rated isolation limits relative to chassis ground on the BNC inputs. Exceeding common-mode voltage tolerances can damage the input amplifier staging and corrupt adjacent channel readings.

❗ Hot-Plugging Sensors While IEPE Power is Active: Avoid hot-plugging piezoelectric microphones or accelerometers while the 4 mA IEPE excitation current is actively enabled if your cabling introduces heavy transient spikes. While the inputs are protected, severe electrostatic discharges or contact bounce can stress the internal input coupling capacitors.

❗ Failing to Allow Adequate Warm-Up Time Before Critical Testing: When taking high-precision acoustic or vibration measurements, always allow the PXI-4472B module a 15-minute warm-up period after powering on the PXI chassis. Allowing the internal components to reach thermal equilibrium ensures ADC reference stability and prevents low-frequency DC drift.

 

Intent-Driven FAQ

Q: What is the primary operational difference between the standard PXI-4472 and the PXI-4472B revision? The PXI-4472B is an updated hardware revision of the original PXI-4472. It features modern component replacements to maintain long-term manufacturing lifecycle viability while preserving complete software and pinout compatibility with existing NI-DAQmx applications.

Q: Do I need external signal conditioning boxes to connect ICP/IEPE accelerometers to the PXI-4472B? No. The PXI-4472B features built-in, software-selectable 4 mA constant current excitation (IEPE) supplies on every channel, allowing you to plug standard ICP accelerometers and microphones directly into the front BNC connectors.

Q: Can I synchronize multiple PXI-4472B modules to measure more than 8 channels simultaneously? Yes. By installing multiple PXI-4472B modules into the same chassis, you can use the PXI trigger bus and 10 MHz reference clock to phase-synchronize dozens of channels down to sub-sample accuracy for large-scale structural test arrays.

Q: What software drivers are required to operate the PXI-4472B in a Windows environment? The PXI-4472B is controlled using the NI-DAQmx driver software. It integrates seamlessly into development environments such as LabVIEW, LabWindows/CVI, C++, and MATLAB via standard DAQmx API function calls.

Q: Is the PXI-4472B compatible with hybrid PXI Express (PXIe) chassis slots? Yes. Like most 3U PXI modules, the PXI-4472B is electrically and mechanically forward-compatible with hybrid PXIe slots, ensuring it operates reliably in modern PXI and PXI Express test systems.