Sale!

ProSoft RLX2-IHNF-W-E | Weatherproof IP67 Industrial Radio | In-Stock

Original price was: ¥999.00.Current price is: ¥888.00.

ProSoft RLX2-IHNF-W-E | Weatherproof IP67 Industrial Radio | In-Stock

  • Exact Model: ProSoft RLX2-IHNF-W-E
  • OEM Brand: ProSoft Technology
  • System Series: RadioLinx Industrial Wireless Architecture
  • Core Function: Delivers high-throughput 802.11a/b/g/n wireless Ethernet routing across outdoor, harsh, or washdown industrial environments.
  • Module Type: Weatherproof IP66/IP67 Dual-Band Industrial Wireless Hotspot
  • Defining Specs: IP66/IP67 die-cast aluminum enclosure, ETSI regional frequency compliance, 3x Type N female antenna ports, sub-10 ms Ultra-Fast Roaming.
Category:

Description

ProSoft RLX2-IHNF-W-E | Weatherproof IP67 Industrial Radio | In-Stock

 

Dynamic Product Introduction

Exposing standard control network equipment to outdoor environments, coastal salt air, or high-pressure washdown bays often leads to moisture ingress and rapid hardware degradation. The ProSoft RLX2-IHNF-W-E solves this structural vulnerability by housing ProSoft’s high-speed industrial hotspot engine inside a heavy-duty, IP66/IP67-rated die-cast aluminum chassis. Replacing indoor-rated radios placed inside secondary junction boxes with this direct-mount outdoor unit removes thermal buildup points while protecting your critical fieldbus wireless links.

Equipped with three external Type N antenna connectors and built-in pole mounting hardware, the ProSoft RLX2-IHNF-W-E simplifies field installation on remote water treatment tanks, port gantry cranes, and mining haul routes. The unit features sub-10 millisecond Ultra-Fast Roaming across 2.4 GHz and 5 GHz ETSI frequency channels, keeping moving machinery connected to main PLC controllers without risking I/O connection drops. For wireless infrastructure managers upgrading legacy serial or Ethernet links outdoors, this radio provides reliable, long-range connectivity built to handle extreme thermal shifts.

RLX2-IHNF-W-E

RLX2-IHNF-W-E

Key Technical Specifications

  • Model Identification: ProSoft RLX2-IHNF-W-E
  • Enclosure Rating: Weatherproof IP66/IP67 die-cast aluminum with integrated pole mount
  • Regulatory Domain: ETSI (“-E” European/International Frequency Variant)
  • Wireless Standards: IEEE 802.11a, 802.11b, 802.11g, 802.11n
  • Antenna Interface: 3x Type N Female Connectors (50 Ohm impedance)
  • Ethernet Interface: 1x 10/100/1000 Mbps M12/RJ45 liquid-tight connector
  • Roaming Latency: Sub-10 ms Ultra-Fast Roaming protocol
  • Power Requirements: 10 to 24 V DC terminal input or 802.3af Power over Ethernet (PoE)
  • Operating Temperature: -40°C to +75°C (-40°F to +167°F)
  • Vibration / Shock: IEC 60068-2-6 (20G, 3-Axis) vibration / IEC 60068-2-27 shock resistant

 

Global Sourcing & Live-Test SOP (Transparency Core)

To guarantee reliable operation in remote or hazardous outdoor installations, every pre-owned or surplus unit undergoes a comprehensive multi-point testing regimen prior to dispatch:

  • Inbound Verification: Serial numbers are verified against OEM regional manufacturing records, optical front seals and weather gaskets are checked for compression wear, and Type N thread arrays undergo mechanical gauge testing.
  • Live Simulation: The radio is powered on a outdoor-simulated bench using both 24 V DC direct feeds and 802.3af PoE sources to confirm automatic power switching and internal regulator stability.
  • RF Diagnostics & Handshake: Utilizing ProSoft IH Browser software, full spectrum sweeps across all ETSI-approved 2.4 GHz and 5 GHz channels are conducted, evaluating 3×3 MIMO RF output levels and verifying sub-10 ms packet handoffs under simulated vehicle movement.
  • Environmental Heat & Pressure Run: The module undergoes an 18-hour continuous transmission soak test at 65°C in an environmental chamber while subjected to positive-pressure seal verification.
  • Final Prep: Radio IP settings are restored to factory defaults, weather-tight port caps are torqued down, and the unit is vacuum-sealed in static-shielding bags containing fresh moisture-absorbing desiccant.

 

The Field Engineer’s Pitfall Guide

❗ Type N Port Termination Integrity: Operating the ProSoft RLX2-IHNF-W-E without attaching properly rated 50-Ohm terminations or outdoor antennas to all three active Type N ports causes RF signal reflection. This reflected power can damage the onboard transmitter power amplifiers over prolonged operation.

❗ Water-Tight M12/RJ45 Cable Sealing Failure: The IP67 rating of the ProSoft RLX2-IHNF-W-E depends on using the original weather-tight gland cable assembly. —In field deployments, I’ve seen outdoor installations flooded because a contractor used a standard commercial RJ45 boot instead of the OEM compression gland, leading to water tracking straight into the Ethernet port.

❗ Coaxial Cable Grounding & Lightning Surge Protection: Failing to ground the coaxial cable shield at the antenna entry point creates an path for atmospheric static buildup. Ensure the external ground lug on the die-cast housing is connected directly to earth ground using low-impedance copper grounding strap.

 

Intent-Driven FAQ

What is the functional difference between the ProSoft RLX2-IHNF-W-E and standard indoor RLX2-IHNF models?

The “-W” suffix designates a heavy-duty IP66/IP67 weatherproof housing for outdoor or washdown locations, while the “-E” suffix limits operating channels to ETSI regulatory frequency standards. The core internal radio architecture remains fully compatible with the standard indoor series.

Can I power the ProSoft RLX2-IHNF-W-E using Power over Ethernet (PoE)?

Yes. The radio supports standard 802.3af PoE over its liquid-tight Ethernet port, as well as an external 10 to 24 V DC auxiliary power supply feed.

How do I restore the radio to factory IP settings if the web interface is locked?

You can use the ProSoft IH Browser diagnostic utility over a local Ethernet connection to discover the hardware MAC address and push a factory network reset command.

Is this outdoor radio safe for installation in Class I, Division 2 hazardous locations?

Specific hazardous area ratings depend on the exact series plate markings. Always verify the ATEX Zone 2 or Class I, Div 2 certification label on the side of the housing before installing the module in explosive gas atmospheres.

What standard warranty is included on reconditioned surplus inventory?

All reconditioned and factory-sealed units include a comprehensive 1-year replacement warranty covering housing seal integrity, Ethernet port transceivers, and internal RF circuit stability.

Business Card