Description
Kollmorgen S72402-NANANA | Digital Servo Drive 24A STO EtherCAT
Dynamic Product Introduction
When high-torque industrial axes—such as large stamping presses or heavy gantry positioning systems—begin tripping under aggressive acceleration ramps, standard low-current drives simply cannot supply the required power headroom. Sourcing a robust replacement like the Kollmorgen S72402-NANANA becomes an absolute necessity for restoring high-duty cycle production lines. Built to handle heavy continuous electrical loads, this high-current digital drive manages massive thermal dissipation and transient current spikes without sacrificing precision trajectory control.
The S72402-NANANA merges high-speed current loop processing with universal feedback decoding, eliminating the drift issues inherent in older analog controllers. Equipped with embedded Safe Torque Off (STO) hardware and native dual EtherCAT/CANopen communication stacks, it interfaces seamlessly with modern multi-axis motion controllers while enforcing rigorous machine safety interlocks.

S72402-NANANA
Key Technical Specifications
The electrical and mechanical parameters outlined below characterize the high-current operational thresholds for the S72402-NANANA digital drive:
- Continuous Output Current: 24 Arms
- Peak Output Current: 48 Arms for up to 5 seconds
- Main Line AC Input Voltage: 3x 208V AC (-10%) to 3x 480V AC (+10%), 50/60 Hz
- DC Bus Link Voltage Range: 290V DC to 675V DC
- Auxiliary Logic Power Supply: 24V DC (±15%) via X3 terminal connector
- Rated Apparent Power Output: 18 kVA capacity
- Safety Hardware: Integrated Safe Torque Off (STO), SIL2 / PL d compliant
- Feedback Compatibility: Resolver, EnDat 2.1/2.2, HIPERFACE, Sine/Cosine, BiSS, Incremental ROD encoders
- Communication Ports: Onboard EtherCAT and CANopen via dual RJ45 sockets and 9-pin D-Sub (X6)
- Mechanical Mounting: Heavy-duty cabinet panel mount with forced-air cooling fan assembly
Global Sourcing & Live-Test SOP (Transparency Core)
Deploying high-power surplus units like the S72402-NANANA into demanding production environments requires strict, multi-tier quality control testing to verify absolute hardware reliability.
Inbound Verification
- Paperwork Tracing: Every incoming S72402-NANANA is cross-checked against original factory shipping manifests and OEM serial registries to block counterfeit or gray-market components.
- Chassis & Terminal Inspection: The cast-aluminum housing, high-current busbars, internal electrolytic capacitors, and cooling fans are rigorously inspected for thermal aging or mechanical wear.
Live Simulation
- Test Rig Powering: The drive is securely bolted to a high-capacity test rack, supplying isolated 24V DC logic power alongside a 3-phase 400V AC main line input.
- Motor Load Hookup: Connected to a heavy-duty industrial test motor equipped with multi-turn absolute encoder feedback.
Diagnostics
- Full-Scale Load Simulation: The unit executes aggressive multi-axis motion profiles using DriveGUI software to stress-test the 48-amp peak power stage and current loop stability.
- Fieldbus Telemetry Check: EtherCAT cyclic process data loops and synchronization clocks are monitored under load for packet jitter or dropped frames.
- Thermal Burn-in Chamber Run: The drive undergoes a continuous 24-hour thermal soak at 85% rated continuous load (20.4 Arms) inside a climate-controlled chamber to verify internal junction temperatures and fan performance.
Final Prep
- Parameter Reset & Firmware Archiving: Configuration registers are reset to factory defaults, parameter files are backed up, and the unit is flashed to standard production firmware.
- ESD & Secure Crating: Enclosed in a heavy anti-static ESD bag with moisture-absorbing desiccant packs, then secured in high-density custom foam crates for transport.
The Field Engineer’s Pitfall Guide
Swapping a high-current unit like the S72402-NANANA during an unexpected breakdown introduces unique physical and electrical risks. Keep these field warnings in mind:
- ❗ DC Bus Capacitor Residual Charge Hazards: Because the S72402-NANANA handles large energy storage capacitors, disconnecting main power does not instantly eliminate dangerous high voltages. I’ve seen technicians suffer severe electrical burns because they touched the X0 power lugs before letting the internal bus bleed down completely. Always verify DC voltage drops below 50V using a calibrated multimeter across the bus terminals before handling power cables.
- ❗ Inadequate Panel Cooling Clearance: The S72402-NANANA generates substantial thermal output under 24A continuous operation. Mounting this drive in a cramped enclosure without respecting the mandated top and bottom airflow clearances will cause premature internal over-temperature faults during peak summer production cycles.
- ❗ EtherCAT Master XML Configuration Mismatches: Swapping out an S72402-NANANA with a different internal firmware version without updating the EtherCAT master configuration file (ESI) will cause the PLC to reject the slave node’s PDO mapping, locking the axis in a persistent communication error state.
Intent-Driven FAQ
Q: Will replacing my faulty S72402-NANANA drive erase my motor tuning and axis parameters? A: Yes, because all operational parameters are saved in the non-volatile EEPROM of the physical drive hardware. You must upload the parameter file via DriveGUI over the serial port before swapping the unit, or manually re-enter the configuration data into the replacement S700 drive.
Q: Can the S72402-NANANA drive operate on a single-phase 230V power supply for testing purposes? A: No, the S72402-NANANA requires a balanced 3-phase AC input (208V to 480V AC). Attempting to power this high-current unit on single-phase AC will trigger an immediate phase-loss fault and cause severe DC bus voltage ripple under load.
Q: What does the “NANANA” model code suffix signify on the S72402-NANANA? A: The “NANANA” designation indicates that option slots 1, 2, and 3 are unpopulated with secondary expansion cards, relying entirely on the built-in EtherCAT, CANopen, and standard feedback interfaces pre-installed on the baseboard.
Q: Is it safe to unplug the motor power connector while the S72402-NANANA is energized? A: Never disconnect motor power lines or feedback cables while the drive is powered on. Live plugging or unplugging on high-current drives produces damaging electrical arcs and can destroy the output power transistors.
Q: How do I clear an active Safe Torque Off (STO) fault code on a newly installed S72402-NANANA? A: Ensure that clean 24V DC logic power is wired correctly to the STO input pins on the safety connector. If your machine safety loop is open or improperly jumpered, the drive will lock out the power stage and refuse to enable.