Sale!

National Instruments SCXI-1102 | Verified OEM Data Acquisition Hardware

Original price was: ¥999.00.Current price is: ¥888.00.

National Instruments SCXI-1102 | Verified OEM Data Acquisition Hardware

  • Exact Model: SCXI-1102 (Part Number: 776572-02 / 181825-01)
  • OEM Brand: National Instruments (NI)
  • System Series: SCXI Signal Conditioning eXtensions for Instrumentation Series
  • Core Function: This 32-channel analog input module amplifies, filters, and multiplexes low-level voltage signals and millivolt thermocouple inputs into a single host DAQ device.
  • Module Type: 32-Channel Thermocouple / Millivolt Signal Amplifier & Multiplexer
  • Defining Specs: 32 differential channels, programmable gains of 1 and 100, 2 Hz low-pass anti-aliasing filters, 250 V RMS bank-to-bus/earth isolation.
Category:

Description

National Instruments SCXI-1102 | Verified OEM Data Acquisition Hardware

 

Dynamic Product Introduction

Field engineers know how quickly thermal validation runs stall when an aging multiplexer card develops channel drift or open-circuit detection faults. Honestly, trying to convert a high-density temperature screening rig to modern C-Series hardware mid-test introduces severe re-cabling expenses, software rewrites, and extended downtime that test managers simply cannot accept. The National Instruments SCXI-1102 resolves this operational bottleneck by serving as a direct drop-in replacement card that preserves existing SCXI chassis slot assignments, signal conditioning logic, and NI-DAQmx tasks.

Engineered specifically for low-noise temperature and millivolt voltage data acquisition, this SCXI-1102 module features 32 differential channels equipped with individual 2 Hz low-pass filters to suppress 50/60 Hz power-line interference. In structural thermal testing and industrial process monitoring cells, replacing a degraded module with a bench-verified SCXI-1102 restores baseline noise rejection and high-accuracy channel scanning instantly—provided you pair it with a calibrated terminal block containing cold-junction compensation (CJC).

SCXI-1102

SCXI-1102

Key Technical Specifications

  • Input Channels: 32 differential analog input channels
  • Supported Input Types: Thermocouples (Types J, K, T, E, R, S, B, N) and low-level ±100 mV / ±10 V voltage signals
  • Programmable Gain Settings: Software-selectable gains of 1 and 100
  • Filter Cutoff Frequency: 2 Hz low-pass filter per channel for power-line noise rejection
  • Isolation Rating: 250 V RMS working isolation (bank-to-earth ground and backplane bus)
  • Multiplexing Architecture: High-speed analog bus output multiplexed into a single DAQ channel
  • Terminal Block Compatibility: SCXI-1300, SCXI-1303 (Isothermal CJC), SCXI-1328
  • Power Requirements: Derived directly from SCXI chassis backplane (+5 VDC and ±15 VDC rails)
  • Operating Temperature Window: 0°C to +50°C ambient operational environment

 

Global Sourcing & Live-Test SOP (Transparency Core)

Sourcing discontinued or secondary-market NI DAQ hardware demands a strict zero-trust quality verification methodology. Inbound shipments of the SCXI-1102 undergo thorough customs documentation audits, serial number checks, and microscopic pin inspections to detect bent backplane DIN connectors, trace swelling, or heat-stressed passive components.

Once logged into inventory, every SCXI-1102 module transitions directly to our specialized DAQ diagnostic test rig. Technicians seat the card into an SCXI-1000 chassis paired with an SCXI-1303 terminal block and a PXI/PCI DAQ controller. We execute a 24-hour thermal soak while scanning all 32 channels with precision DC millivolt sources and thermocouple simulators. Noise rejection ratios, gain linearity across 1x/100x settings, and backplane multiplexing timing are fully verified before sealing the SCXI-1102 in anti-static ESD packaging prior to dispatch.

 

The Field Engineer’s Pitfall Guide

❗ Unchecked Cold-Junction Compensation (CJC) Configurations: Installing the SCXI-1102 with an SCXI-1300 terminal block without verifying CJC sensor enabling in NI-DAQmx or Measurement & Automation Explorer (MAX) will result in massive temperature measurement offsets proportional to ambient room variation.

❗ Applying High-Voltage Transients Above 250 V RMS: Exceeding the 250 V RMS isolation boundary on field wiring will damage internal multiplexer switches and burn out front-end protection diodes across multiple adjacent channels.

❗ Hot-Plugging Module into an Energized Chassis: Inserting or unseating the SCXI-1102 while the SCXI chassis backplane is energized can cause voltage spikes that corrupt onboard module EEPROM settings or disrupt active DAQmx driver sessions.

 

Intent-Driven FAQ

Will I need to rewrite my NI-DAQmx measurement code when replacing an SCXI-1102 module? No, because the SCXI-1102 contains an onboard EEPROM, NI-DAQmx automatically detects the module in its assigned chassis slot and maintains existing channel configuration tasks.

Can the SCXI-1102 measure standard ±10V voltage signals alongside thermocouples? Yes, each channel can be configured for a gain of 1 to measure higher voltage inputs up to ±10V, or a gain of 100 for millivolt and thermocouple-level signals.

Are surplus National Instruments SCXI-1102 modules supplied in original factory packaging? Inventory conditions range from brand-new old stock (NOS) in original NI boxes to certified pre-owned surplus. Regardless of outer packaging condition, every SCXI-1102 module undergoes a complete 32-channel bench calibration and burn-in test before dispatch.

What causes persistent open-thermocouple error readings across multiple channels? Persistent open-circuit errors typically point to loose screw terminals on the attached terminal block, a damaged 96-pin DIN front connector, or a blown input protection diode caused by an overvoltage spike.

What warranty coverage applies to a replacement SCXI-1102 module? Our secondary-market and surplus National Instruments SCXI-1102 modules include a comprehensive 12-month operational warranty covering gain linearity, multiplexing logic, channel isolation, and backplane bus stability under standard operating conditions.