Sale!

Rexroth RAC2.2-250-460-A0-W1 | Indramat Main Spindle Drive Controller

Original price was: ¥999.00.Current price is: ¥888.00.

Rexroth RAC2.2-250-460-A0-W1 | Indramat Main Spindle Drive Controller

  • Exact Model: RAC2.2-250-460-A0-W1
  • Material Part Number: RAC2.2-250-460-A0-W1 (OEM Indramat designation)
  • OEM Brand: Bosch Rexroth (Indramat)
  • System Series: RAC 2 Series Main Spindle Drive Controllers (Line 2, Version 2)
  • Core Function: Provides precise, closed-loop speed, position, and orientation control for high-power 2-pole and 4-pole Indramat 2AD and 1MB AC asynchronous main spindle motors used in heavy CNC machine tools.
  • Module Type: High-Power AC Main Spindle Controller / Inverter
  • Defining Specs: 250 A continuous output current rating, 460 V AC 3-phase line connection, analog/digital interface (A0), internal blower/fan cooling with internal heat dissipation (W1).
Category:

Description

Rexroth RAC2.2-250-460-A0-W1 | Indramat Main Spindle Drive Controller

 

Dynamic Product Introduction

CNC machine tool engineers and plant maintenance supervisors running high-capacity milling centers, heavy turning lathes, or transfer lines know how catastrophic a main spindle drive failure can be to factory output. When a primary spindle controller experiences power transistor short-circuiting, line-sync loss, or internal thermal trip, replacing the unit without altering CNC interface parameters or electrical cabinet cooling architecture is an urgent operational priority.

The Bosch Rexroth Indramat RAC2.2-250-460-A0-W1 is a high-performance AC main spindle drive controller engineered specifically for high-torque spindle applications. Delivering a massive 250 A output current profile on a 460 V 3-phase AC line, this drive powers Indramat 2AD frame induction motors and 1MB frameless spindle motors. Featuring high-precision C-axis positioning, spindle orientation (indexing), regulated regenerative mains feedback, and an internal cooling blower (W1 configuration), the RAC2.2 provides low-speed high-torque cutting performance alongside smooth high-speed finishing runs up to maximum motor limits.

RAC2.2-250-460-A0-W1

RAC2.2-250-460-A0-W1

Key Technical Specifications

  • Controller Line & Version: RAC 2 Series, Line 2, Version 2 (RAC2.2)
  • Rated Continuous Current: 250 A
  • Mains Input Voltage: 3-phase 400 to 460 V AC (50/60 Hz line input)
  • Command Communication Interface: A0 (Standard analog ±10 V velocity command input with digital control lines)
  • Heat Dissipation / Cooling Type: W1 (Internal cooling fan blower; air drawn from inside cabinet and exhausted out top)
  • Supported Motor Types: Indramat 2AD main spindle motors and 1MB frameless spindle motors
  • Positioning Capabilities: Spindle orientation (spindle positioning) and C-axis contouring mode
  • Mains Feedback / Regeneration: Integrated line-regeneration circuit (returns braking kinetic energy back to factory 3-phase AC grid)
  • Diagnostics: Front-panel 2-digit alphanumeric LED diagnostic status display
  • Enclosure Rating: Heavy-duty panel-mount industrial IP20 steel enclosure

High-Voltage Electrical Safety Hazard

The RAC2.2-250-460-A0-W1 operates on 460 V AC 3-phase mains and generates an internal DC bus in excess of 700 V DC. Always disconnect the main circuit breaker and 24 V DC control feeds, then wait at least 5 minutes for internal filter capacitor banks to fully discharge. Measure voltage across the DC bus terminals (must read below 50 V DC) before touching high-power terminal lugs or removing protective covers.

 

Global Sourcing & Live-Test SOP (Transparency Core)

Sourcing legacy high-power spindle controllers requires thorough power-stage, thermal, and dynamic load testing to guarantee high-torque capability and line-regeneration performance.

Inbound Verification & Traceability

  • Paperwork Audit: Verification of serial numbers, revision plates, and full model type code string RAC2.2-250-460-A0-W1 against OEM Indramat production logs to validate hardware configuration and option card slots.
  • Physical Inspection: Comprehensive examination of 3-phase high-current terminal lugs, internal busbar plating, high-voltage electrolytic capacitor health (checking for leakage or dome bulging), internal cooling fan blades, and front-panel diagnostic boards.

Live Bench Simulation & Diagnostics

  • Pre-Charge & Mains Synchronization Test: Powered up using 460 V AC 3-phase mains to verify soft-charge relay sequencing, 700 V DC bus stabilization, and internal 24 V DC auxiliary rail output.
  • Closed-Loop Spindle Run: Coupled to an authentic Indramat 2AD high-power asynchronous spindle motor equipped with high-resolution feedback to perform acceleration/deceleration sweeps up to 6,000+ RPM.
  • Spindle Orientation & C-Axis Test: Executing high-precision spindle positioning commands (M19 orientation) and low-speed C-axis interpolation steps to monitor shaft holding torque and angle alignment.
  • Line Regeneration Stress Check: Executing rapid spindle deceleration profiles from maximum speed to confirm seamless power regeneration back into the 3-phase AC mains grid without tripping over-voltage limits.
  • 24-Hour Full-Load Thermal Burn-In: Drive undergoes a continuous 24-hour thermal chamber stress run at 250 A duty cycle simulation to ensure cooling fan airflow and IGBT junction temperatures stay well within factory safety margins.

Final Prep

  • Option Board Verification: Checking installed plug-in personality modules (such as auxiliary encoder input cards or bus interfaces).
  • ESD & Heavy Freight Packaging: Unit is bolted into a custom shock-mounted wooden crate with anti-static barrier wrapping and desiccant packs prior to air or ground freight dispatch.

 

The Field Engineer’s Pitfall Guide

  • ❗ Matching the Personality Plug / Firmware Module: The RAC2.2 relies on an internal plug-in programming module (personality card) that contains motor parameter tables, maximum speed limits, and control loop gain settings for your specific 2AD/1MB motor. Installing a replacement RAC2.2 drive without transferring your original programming module will result in startup parameter faults (e.g., “AS” or “FF” errors) or severe motor overheating.
  • ❗ Blower Airflow Clearance Requirements (W1 Model): The “W1” cooling variant draws air from inside the control cabinet and exhausts hot air out the top of the unit. Ensure a minimum of 200 mm clearance above and below the drive housing inside the electrical enclosure to prevent hot air recirculation and thermal trip-outs.
  • ❗ Commutating Choke / Line Reactor Installation: Operating the RAC2.2 without the mandatory external Indramat line reactor (commutation choke) on the 460 V AC input line will cause high peak currents, harmonic distortion, and immediate damage to the internal mains-regeneration thyristor bridge.

 

Intent-Driven FAQ

Will replacing my RAC2.2-250-460-A0-W1 require tuning the drive with a PC?

If you transfer your original personality module / programming card from the old drive into the replacement unit, no software re-tuning is required. The replacement card automatically loads your machine’s exact motor data, speed limits, and tuning constants upon power-up.

What is the difference between RAC2.1 and RAC2.2 series drives?

The RAC2.2 represents an upgraded hardware revision (Series 2) featuring improved thermal management, refined mains regeneration control circuits, updated IGBT gate driver protection, and enhanced diagnostic alarm tracking compared to the older RAC2.1 baseline.

What does an “AO” or “A0” code in the model number signify?

The “A0” designation specifies the primary command interface module installed in the drive. It indicates standard analog velocity command inputs (±10 V DC) paired with discrete digital control inputs/outputs for drive enable, spindle orientation, and fault status outputs.

How do I clear an “Overvoltage” or DC bus trip on deceleration?

DC bus over-voltage during spindle deceleration indicates a problem in the mains regeneration circuit, a blown AC line fuse, or an improperly sized/missing external line choke that prevents power from being returned to the AC grid.

What warranty coverage is provided on replacement hardware?

All verified Rexroth Indramat RAC2.2-250-460-A0-W1 spindle drives include a standard 12-month full-replacement warranty covering high-power IGBT stages, 700 V DC bus regulation, mains-regeneration logic, and internal blower fan assemblies.

If you need help identifying programming module slots, verifying 460 V line reactor wiring, or setting up spindle orientation parameters for your RAC2.2 setup, let me know your machine tool model and I can guide you through the process.