Sale!

ICS Triplex T8480C | Conformal-Coated TMR 40-Ch Analog Output

Original price was: ¥999.00.Current price is: ¥888.00.

ICS Triplex T8480C | Conformal-Coated TMR 40-Ch Analog Output

  • Model: ICS Triplex T8480C (Rockwell Automation Publication ICSTT-RM284P-EN-P / PD-T8480; conformal-coated version of T8480)
  • Brand: ICS Triplex / Rockwell Automation
  • Series: Trusted Triple Modular Redundant (TMR) Safety System
  • Core Function: Conformal-coated, fault-tolerant 40-channel 4–20 mA Triple Modular Redundant (TMR) analog output module driving modulating control valves, turbine governors, and proportional actuators with triplicated voltage/current loop diagnostics in corrosive environments.
  • Product Type: Conformal-Coated Trusted TMR 40-Channel Analog Output Module
  • Key Specs: Factory conformal coating (C suffix), 40 analog output channels across 5 isolated power groups (8 channels per group), 1–22 mA continuous output range (4–20 mA recommended), ±0.1% full-scale calibration accuracy at +25°C (±0.25% over 0–60°C), <50 ms step response, 18–32V DC field supply (0.9 A max), 20–32V DC backplane supply (22 W).
  • Status: Mature / Surplus OEM Safety Hardware Available
Category:

Description

ICS Triplex T8480C | Conformal-Coated TMR 40-Ch Analog Output

 

Product Introduction

When an offshore oil and gas production platform, coastal LNG liquefaction terminal, or sour-gas petrochemical refinery modulates proportional control valves and turbine governors in salt-fog, high-humidity, or sulfur-bearing atmospheres, uncoated analog output cards risk PCB corrosion and leakage drift across precision current loops. The ICS Triplex T8480C is not a digital input card (despite occasional mislabeled surplus broker listings) or an uncoated T8480 module; it is the factory conformal-coated (C suffix) 40-channel Triple Modular Redundant (TMR) Analog Output module engineered specifically for harsh-environment Rockwell Automation / ICS Triplex Trusted safety installations. Slotted into any single-wide I/O slot of a T8100 controller chassis or T8300 expander chassis, this model consolidates 40 current-loop outputs into five isolated groups of eight channels.

Built with triplicated circuitry and protective PCB coating, the ICS Triplex T8480C continuously measures both voltage and current across every voted channel to maintain operation when internal faults occur. It delivers a 1 to 22 mA continuous output range (4–20 mA recommended) with ±0.1% full-scale calibration accuracy at +25°C and <50 ms step response—though your mileage may vary depending on total loop load resistance versus available 18–32V DC field supply voltage, non-interfering loop classification, and Intrinsic Safety (IS) barrier voltage drop. Installing a verified surplus ICS Triplex T8480C restores high-density analog loop control in corrosive environments without modifying existing Field Termination Assemblies.

T8480C

T8480C

Key Technical Specifications

  • Manufacturer Part Number: T8480C (ICS Triplex / Rockwell Automation; Publication ICSTT-RM284P-EN-P / PD-T8480; C designates factory conformal coating)
  • Safety & Platform Architecture: Trusted Triple Modular Redundant (TMR) architecture with triplicated channel circuitry and continuous voltage/current readback diagnostics
  • Environmental Protection: Factory-applied conformal coating (CCoat / C option) shielding internal PCB assemblies against corrosive gases, salt mist, and condensation
  • Output Channel Architecture: 40 analog current-loop output channels arranged in 5 isolated power groups of 8 channels each
  • Output Current Range & Accuracy: 1 mA to 22 mA continuous output range (4–20 mA recommended); ±0.1% of full scale calibration accuracy at +25°C; ±0.25% of full scale overall accuracy across 0°C to +60°C
  • Off-State Leakage & Step Response: 350 µA maximum off-state leakage at 24V DC; <50 ms step response (1 mA to 20 mA step to within 1% of final value)
  • Field Supply & Backplane Power: 18V to 32V DC external field supply (0.9 A maximum field-supply current); 20V to 32V DC dual-redundant backplane supply (22 W backplane power)
  • Diagnostics & Protection: Triplicated per-channel voltage and current measurement diagnostics, open/short-circuit line monitoring, automatic per-channel over-current protection (no external fuses required), and 1 ms Sequence of Events (SOE) reporting
  • Physical & Environmental: 266 mm (H) x 31 mm (W) x 303 mm (D) (10.5″ x 1.2″ x 12.0″), weight approx. 1.2 kg to 1.3 kg; 0°C to +60°C operating temperature (-25°C to +70°C storage), 10% to 95% non-condensing RH

 

Application Scenarios & Pain Points

Offshore Platforms & Coastal Chemical Turbine/Valve Control: Marine salt spray and airborne sulfur compounds accelerate PCB trace corrosion inside remote marshalling cabinets feeding turbine governors, compressors, and modulating control valves. Installing the ICS Triplex T8480C delivers ±0.1% calibration accuracy and <50 ms step response across 40 TMR 4–20 mA channels while shielding internal circuitry with factory conformal coating.

With vs. Without Conformal-Coated (C Suffix) Triplicated Loop Readback: Standard uncoated analog output cards exposed to ISA-S71.04 G3 corrosive atmospheres suffer leakage drift and cannot tell operators when a field positioner coil opens or a marshalling cable shorts. With factory conformal coating and independent per-slice voltage and current readback built into this model, corrosive contaminants are sealed out while open-circuit and short-circuit faults are flagged immediately.

Online Hot-Replacement via Companion Slot or SmartSlot: Continuous petrochemical and refining units cannot shut down active process loops to swap a faulted analog card. Configuring the ICS Triplex T8480C in a dedicated Companion (adjacent) Slot or SmartSlot redundant group supports live online replacement without bumping active 4–20 mA outputs.

 

QA & Live Testing SOP (Trust Signal)

Every ICS Triplex T8480C conformal-coated 40-channel TMR analog output module in our warehouse undergoes thorough electrical, per-channel 4–20 mA accuracy, and coating-integrity verification before shipment. Our safety-system technicians inspect the single-wide housing, top/bottom ejector latches, front per-channel status LED matrix, and rear high-density backplane pins under magnification for bent contacts or mechanical wear, verify uniform factory conformal coating without flaking, and test field-to-backplane galvanic isolation and 24V DC power rails on a Fluke precision multimeter.

Following static bench checks, the module is installed into an energized T8100 Trusted test chassis equipped with a T8110B TMR processor and connected via a 40-channel rear cable to a compatible Field Termination Assembly and automated 40-channel precision shunt/load test fixture. We command 1 mA, 4 mA, 12 mA, 20 mA, and 22 mA output setpoints across all 40 channels, verify ±0.1% full-scale accuracy at +25°C, confirm <50 ms step response and 350 µA max off-state leakage, and validate open/short-circuit line monitoring and triplicated slice readback in Trusted Toolset. Once fault-free TMR performance is proven, the backplane pins are shielded, the module is wrapped in heavy anti-static ESD protection, and packed in custom high-density foam.

 

Field Engineer’s Pitfall Guide

❗ Non-Interfering vs. Safety-Output Loop Suitability (Publication ICSTT-RM284P-EN-P): Per Rockwell Automation Publication ICSTT-RM284P-EN-P / PD-T8480 application notes, the ICS Triplex T8480C provides current-loop outputs with triplicated voltage and current diagnostics intended for non-interfering modulating control and monitoring duties—do not assume unrestricted safety-shutdown output suitability without verifying your loop’s safety integrity design requirements.

❗ Load Resistance vs. Field Supply Voltage Headroom & IS Barriers: Always confirm your total loop resistance (valve positioner impedance + cable resistance + Intrinsic Safety barrier drop) against the manufacturer load-resistance graph for your available 18–32V DC field supply voltage so the module can drive a full 20–22 mA without saturating. Furthermore, the is not approved for direct hazardous-area connection without external Intrinsic Safety (IS) barriers.

❗ Matching Conformal-Coated Companion Hardware & Gas-Free Live-Swap Rules: Plants specifying C-suffix hardware for corrosive environments should pair the with matching conformal-coated Field Termination Assemblies and chassis (T8100C / T8300C) so the entire loop retains uniform environmental protection. Although online changeover is supported via Companion Slot or SmartSlot configurations, never insert or extract modules or disconnect field wiring while circuits are energized unless the cabinet location is verified free of ignitable concentrations.

 

Intent-Driven FAQ

Q: What does the C suffix signify in the ICS Triplex T8480C part number?A: The C suffix designates factory-applied conformal coating (CCoat) on the internal printed circuit boards, protecting the 40-channel Trusted TMR Analog Output module against corrosive gases, salt fog, and high humidity.

Q: Is the ICS Triplex T8480C electrically interchangeable with the standard T8480? A: Yes. The shares identical electrical ratings (40 channels in 5 groups of 8, 1–22 mA continuous range, 18–32V DC field supply, ±0.1% calibration accuracy at +25°C) and pinout with the standard T8480, making it a direct functional replacement with added environmental protection.

Q: Why do some online surplus listings mistakenly call the T8480C a digital input module? A: Secondary surplus brokers occasionally misclassify the as a 24V DC digital input card in catalog titles, whereas per Rockwell Automation Publication PD-T8480 / ICSTT-RM284P-EN-P it is strictly a 40-channel 4–20 mA Trusted TMR Analog Output module.

Q: What is the calibration accuracy and step response speed of the T8480C?A: This model delivers ±0.1% of full-scale calibration accuracy at +25°C (±0.25% across 0°C to +60°C) and a step response of less than 50 ms for a 1 to 20 mA step within 1% of final value.

Q: Are these ICS Triplex T8480C analog output modules genuine OEM surplus units? A: Yes. We stock authentic original US-manufactured OEM ICS Triplex / Rockwell Automation hardware complete with factory serial labels, verified conformal coating, and inspected backplane connectors.

Q: What warranty applies to this conformal-coated Trusted 40-channel TMR analog output module?A: All new surplus ICS Triplex T8480C modules ship backed by a full 1-year replacement warranty covering electrical functionality and 4–20 mA loop calibration accuracy.

Business Card