Sale!

ICS Triplex T8314 | Trusted Fibre Optic TX/RX Transceiver Unit

Original price was: ¥999.00.Current price is: ¥888.00.

ICS Triplex T8314 | Trusted Fibre Optic TX/RX Transceiver Unit

  • Model: ICS Triplex T8314 (Rockwell Automation Publication PD_T8314)
  • Brand: ICS Triplex / Rockwell Automation
  • Series: Trusted Triple Modular Redundant (TMR) Safety System
  • Core Function: High-speed DIN-rail fibre-optic transmitter/receiver (TX/RX) converter extending the 250 Mbps Trusted Expander Bus over single-mode optical fiber up to 10 km using a non-interfering Grey Channel architecture.
  • Product Type: Trusted Fibre Optic Transmitter/Receiver (TX/RX) Unit
  • Key Specs: Up to 10 km single-mode fiber transmission distance, Square Connector (SC) duplex optical ports (TX and RX), dual diode-ORed 24V DC power inputs (18–32V DC operating range, 1.7 W max power consumption), -15 dBm min transmitter power, -28 dBm receiver sensitivity, 320 g (0.7 lb) weight.
  • Status: Mature / Surplus OEM Safety Hardware Available
Category:

Description

ICS Triplex T8314 | Trusted Fibre Optic TX/RX Transceiver Unit

 

Product Introduction

When an offshore oil and gas Emergency Shutdown (ESD) system, distributed tank farm, or blast-proof control room must locate remote T8300 I/O expander chassis beyond the 30-meter limit of shielded copper TC-301 cabling, electrical bus extenders expose safety channels to ground potential differences and electromagnetic surge. The ICS Triplex T8314 is not a generic industrial media converter or multi-mode Ethernet switch; it is a specialized 250 Mbps single-mode fibre-optic Transmitter/Receiver (TX/RX) unit engineered specifically for the Rockwell Automation / ICS Triplex Trusted TMR safety platform. Mounted on standard TS32 or TS35 DIN rails inside rear cabinet bays, this model converts differential copper Expander Bus signals into single-mode optical signals.

Deployed in three completely independent pairs (six units and six optical fibers per remote chassis link), the ICS Triplex T8314 implements a non-interfering “Grey Channel” safety communication path over distances up to 10 kilometers. Each unit operates with zero pre-installation software configuration and accepts dual diode-ORed 24V DC power feeds while drawing just 1.7 W maximum—though your mileage may vary depending on single-mode fiber attenuation budgets, SC connector cleanliness, and matched channel fiber length tolerances. Installing a verified surplus ICS Triplex T8314 restores long-distance SIL 3 remote I/O expansion without altering validated controller safety programs.

T8314

T8314

Key Technical Specifications

  • Manufacturer Part Number: T8314 (ICS Triplex / Rockwell Automation; Publication PD_T8314)
  • Safety & Communication Architecture: Non-interfering “Grey Channel” optical extension for the 250 Mbps Trusted TMR Expander Bus (requires 6 units and 6 single-mode fibers per remote link: 3 at local controller end, 3 at remote expander end)
  • Maximum Transmission Distance: Up to 10 km (6.2 miles) over single-mode optical fiber (BICC Brand-Rex Helios Optical Single Mode Fibre Cable recommended)
  • Optical Connector Type: Duplex Square Connector (SC) receptacles (separate TX and RX ports)
  • Optical Power & Sensitivity: -15 dBm minimum transmitter power into fiber; -28 dBm receiver sensitivity (compliant with TR-NWT-000253 and ITU-T G.957 optical eye opening)
  • Propagation & Fiber Length Limits: 80 ns maximum propagation time difference across channels; 15 m maximum fiber length difference between the three TMR fiber pairs
  • Power Supply & Consumption: Dual 24V DC diode-ORed power inputs (18V DC to 32V DC operating range); 1.7 W maximum power consumption per unit
  • Associated Copper Interface Cables: Mates with TC-302-01 (outgoing cable from T8312 Expander Interface Adapter to T8314) and TC-303-01 (incoming cable from to T8310 / T8300 remote expander)
  • Mounting & Dimensions: Horizontal or vertical TS32 / TS35 DIN-rail mounting; 84 mm (H) x 110 mm (W) x 40 mm (D) (3.3″ x 4.3″ x 1.6″); weight 320 g (0.7 lb)
  • Environmental Ratings: 0°C to +60°C (+32°F to +140°F) operating temperature (-25°C to +70°C non-operating), 10% to 95% non-condensing relative humidity

 

Application Scenarios & Pain Points

Long-Distance Blast-Proof Control Room to Field Marshalling Links: Petrochemical complexes and LNG terminals frequently separate central control buildings from hazardous process zones by several kilometers. Installing six ICS Triplex T8314 units (three per end) extends deterministic 250 Mbps Trusted Expander Bus I/O up to 10 km with complete galvanic and lightning surge immunity.

With vs. Without Triplicated Grey-Channel Optical Transceivers: Standard dual-port industrial media converters lack deterministic skew control and create common-cause failure risks across redundant safety buses. With three physically independent pairs of this model operating as non-interfering Grey Channels, any single optical transceiver or fiber break is isolated and voted out by the Trusted TMR hardware without interrupting process safety.

Zero-Configuration Field Replacement: Complex managed optical switches require IP addressing, VLAN configuration, and firmware matching during emergency maintenance. Every ICS Triplex T8314 requires zero pre-configuration before installation—technicians simply snap the replacement onto the DIN rail and land the dual 24V DC, SC fiber, and TC-302/TC-303 cables.

 

QA & Live Testing SOP (Trust Signal)

Every ICS Triplex T8314 Fibre TX/RX Unit in our warehouse undergoes thorough optical, electrical, and high-speed bus verification before shipment. Our safety-system technicians inspect the DIN-rail mounting latch, dual 24V DC power terminals, Expander Bus D-sub interface, and duplex SC optical receptacles under a fiber-inspection microscope for dust, scratches, or mechanical wear, and verify diode-ORed power input isolation on a Fluke precision multimeter.

Following static bench checks, the unit is mounted onto a TS35 DIN rail and powered via dual 24V DC supplies (18–32V DC test sweep) while connected through calibrated single-mode optical attenuators and SC patch cords to a companion reference transceiver and Trusted Expander Bus link. Using a calibrated optical power meter and live T8100 / T8300 chassis test bench, we verify transmitter launch power (>= -15 dBm), receiver sensitivity down to -28 dBm, and error-free 250 Mbps Expander Bus frame transmission. Once optical eye integrity and bus stability are proven, dust caps are fitted to both SC ports, the unit is sealed in anti-static ESD shielding, and packed in custom high-density foam.

 

Field Engineer’s Pitfall Guide

❗ Strict 15-Meter Fiber Length Difference & 200 mm Side Clearance: Per Rockwell Automation Publication PD_T8314, each remote Trusted link requires six units (three at the local T8100 cabinet and three at the remote T8300 cabinet) connected over six single-mode fibers whose physical lengths must not differ by more than 15 meters (maximum 80 ns propagation time difference). During DIN-rail layout, leave at least 200 mm of free clearance on either side of each unit to protect single-mode fiber bend radii.

❗ Correct Outgoing vs. Incoming Copper Cable Selection (TC-302-01 vs. TC-303-01): Do not swap the short copper Expander Bus cables connecting the rear chassis adapters to the transceivers. Use TC-302-01 for the outgoing link from the T8312 Expander Interface Adapter to the local units, and TC-303-01 for the incoming link from the remote units to the T8310 / T8300 remote expander chassis.

❗ Eye-Safe Laser & Hazardous Area Live-Disconnect Precautions: Although the ICS Triplex T8314 operates within TR-NWT-000253 and ITU-T G.957 Class 1 eye-safety limits, never look directly into active SC optical ports or unmated fiber ends without protective dust caps. Furthermore, never connect or disconnect power, copper bus, or fiber cables while circuits are energized unless the hazardous location is verified free of ignitable concentrations.

 

Intent-Driven FAQ

Q: How many ICS Triplex T8314 units are required for a single remote expander link?A: Six units and six single-mode optical fibers are required per remote link—three independent units mounted at the local controller cabinet and three at the remote T8300 expander cabinet.

Q: What is the maximum transmission distance supported by the T8314?A: This model extends the 250 Mbps Trusted Expander Bus over single-mode optical fiber up to 10 kilometers (6.2 miles).

Q: Does the ICS Triplex T8314 require any software or DIP-switch configuration? A: No. Individual units require zero configuration prior to installation within a remote Trusted communications link.

Q: What power supply and optical connectors does this unit use?A: It accepts dual diode-ORed 24V DC power inputs (18V to 32V DC range, 1.7 W max power consumption) and uses Square Connector (SC) duplex ports for single-mode TX and RX fibers.

Q: Are these ICS Triplex T8314 fibre units genuine OEM surplus hardware? A: Yes. We stock authentic original US-manufactured OEM ICS Triplex / Rockwell Automation hardware complete with factory serial labels, clean SC optical receptacles, and intact DIN-rail clips.

Q: What warranty applies to this Trusted Fibre TX/RX Unit?A: All new surplus ICS Triplex T8314 units ship backed by a full 1-year replacement warranty covering optical transceiver performance and electrical functionality.

Business Card