Description
Honeywell SC-UCMX01 51307195-175 | Universal Control Network Module Specs
Dynamic Product Introduction
Few emergencies in an integrated chemical plant or oil refinery carry higher operational risk than a UCN board failure on a critical Honeywell TDC 3000 node. Honestly, attempting to upgrade a legacy Universal Control Module node to a modern Experion C300 controller during an unplanned unit outage requires massive software rewrites, field wiring retrofits, and prolonged downtime. The Honeywell SC-UCMX01 51307195-175 resolves this critical control room hardware failure by serving as a direct drop-in replacement that preserves existing node addresses, database schemas, and backplane slot assignments.
Engineered specifically for continuous-process DCS environments, this SC-UCMX01 51307195-175 board manages deterministic token-passing network traffic across redundant UCN A/B coaxial channels while handling high-density regulatory and sequence logic execution. In plant maintenance operations, replacing a faulted or memory-errored module with a bench-verified 51307195-175 restores complete control node redundancy instantly—provided you restore node parameter backups from the History Module engineering station prior to putting the controller online.

SC-UCMX01 51307195-175
Key Technical Specifications
- Part Number: 51307195-175 (Replaces legacy variants 51307195-100 / 51307195-150)
- Model Assembly: SC-UCMX01 UCN Interface Processor Board
- Network Protocol: Universal Control Network (UCN) 5 MHz token-passing coaxial bus
- Bus Redundancy: Supports dual-redundant Cable A and Cable B coaxial transceiver channels
- Memory Architecture: High-density RAM with battery-backed non-volatile parameter storage
- Execution Speed: High-speed real-time loop updating and sequence control execution
- Operating Power: Powered via 5 VDC and 24 VDC rails from the High-Performance Process Manager (HPM) / UCM rack supply
- Board Mounting: Double-width slot plug-in card for Honeywell 19-inch process card chassis
- Operating Temperature Window: 0°C to +60°C ambient cabinet operational environment
Global Sourcing & Live-Test SOP (Transparency Core)
Sourcing discontinued Honeywell DCS hardware requires a zero-trust quality assurance framework to prevent process trips on high-value industrial assets. Inbound shipments of the SC-UCMX01 51307195-175 undergo strict customs paperwork verification, part number matching, and microscopic component-level checks to detect reflowed ICs, electrolytic capacitor swell, or edge-connector gold wear.
Once logged into inventory, every 51307195-175 board moves directly to our specialized Honeywell TDC 3000 diagnostic bench. Technicians seat the card into an active UCM/HPM test rack connected to a dual-coax UCN network segment. We load a full process control project from a TDC 3000 Native Solution workstation, executing a 24-hour continuous loop processing burn-in. Automatic UCN Cable A to Cable B failover switching, battery backup parameter retention, and backplane bus stability are fully audited using an oscilloscope before sealing the SC-UCMX01 in anti-static ESD packaging prior to dispatch.
The Field Engineer’s Pitfall Guide
❗ Node Address Rotary Switch Misconfigurations: Forgetting to match the physical rotary node address switches on the edge of the replacement 51307195-175 board to the original card’s UCN node address will cause network address conflicts, resulting in a total node disconnect from the Local Control Network (LCN) bridge.
❗ Depleted Lithium Backup Battery: Installing an SC-UCMX01 board without checking the voltage on the onboard lithium battery will lead to immediate loss of database parameters during a cabinet power cycle. Always verify or replace the battery before seating the board into the rack.
❗ Improper UCN Coax Connector Torque: Over-tightening or leaving BNC T-connectors loose on the UCN Cable A/B ports can break the internal coaxial jack solder joints on the 51307195-175 board, causing intermittent node drops and cable error alarms across the entire UCN segment.
Intent-Driven FAQ
Will I need to reload the control project software when replacing an SC-UCMX01 board? Yes, because memory on the 51307195-175 board is volatile without battery backup, replacing a board requires performing a node load (NLOAD) from the History Module (HM) or Universal Station (US) to restore regulatory control blocks.
Is the 51307195-175 revision backward compatible with older 51307195-100 boards? Yes, the 51307195-175 is a direct functional upgrade for earlier 51307195 series UCMX boards, offering improved component heat dissipation and memory stability.
Are surplus Honeywell 51307195-175 boards supplied in original factory packaging? Stock availability ranges from brand-new old stock (NOS) in original Honeywell factory packaging to certified pre-owned surplus. Regardless of outer box condition, every 51307195-175 board passes a full TDC 3000 test-chassis burn-in before dispatch.
What causes a solid RED ‘FAIL’ LED on the SC-UCMX01 front edge indicator? A solid red FAIL light indicates an internal hardware diagnostic failure, RAM parity error, corrupted system firmware, or missing 5 VDC logic power from the chassis power supply.
What warranty coverage applies to a replacement SC-UCMX01 board? Our secondary-market and surplus Honeywell SC-UCMX01 51307195-175 modules include a comprehensive 12-month operational warranty covering CPU processing, memory retention, and UCN network transceiver stability under standard operating conditions.