Sale!

GE IS215UCVEM08 | Mark VI UCVE Controller Module

Original price was: ¥999.00.Current price is: ¥888.00.

GE IS215UCVEM08 | Mark VI UCVE Controller Module

  • Exact Model: IS215UCVEM08
  • OEM: General Electric (GE)
  • Product Family: Mark VI Speedtronic
  • Functional Acronym: UCVE
  • Product Type: Single-slot VME controller / PC control module
  • Primary Function: Executes turbine-control processing and interfaces with the Mark VI control system
  • Ethernet: One Ethernet port, per supplier documentation
  • Serial Interfaces: COM1 and COM2, RS-232C
  • Additional Interfaces: SVGA service-monitor port and keyboard/mouse connections
  • Status Indicators: Three LEDs, per supplier documentation
  • Alternate Reference: UCVE08A, listed by Radwell
  • Procurement Note: Verify exact board markings, installed software, and controller configuration before replacement
Category:

Description

GE IS215UCVEM08 | Mark VI UCVE Controller Module

 

Product Introduction

A controller replacement is not just a matter of matching the board outline. The GE IS215UCVEM08 is a Mark VI UCVE controller used in GE Speedtronic turbine-control applications. It is identified by suppliers as a single-slot controller with Ethernet and serial interfaces, plus service connections for a monitor and keyboard/mouse.

The IS215UCVEM08 is associated with GE’s legacy Mark VI control platform. Supplier documentation identifies one Ethernet port, two RS-232C serial ports, three status LEDs, and a service SVGA port. Radwell also lists the UCVE08A alternate reference and describes the unit as a discontinued PC control module. Exact processor, memory, software image, and configuration details should be confirmed from the actual board and applicable GE documentation before purchase.

For maintenance teams, the practical concern is whether the replacement carries the correct controller hardware and software environment for the installed turbine. A controller that powers up is not necessarily ready to assume the original machine’s control role.

IS215UCVEM08

IS215UCVEM08

Key Technical Specifications

  • Manufacturer: General Electric
  • Model: IS215UCVEM08
  • Functional Acronym: UCVE
  • Series: Mark VI Speedtronic turbine control
  • Module Type: Single-slot VME controller / PC control module
  • Controller Function: Turbine-control processing
  • Ethernet Interface: One Ethernet port, per supplier documentation
  • Serial Communication: Two RS-232C ports, COM1 and COM2
  • Service Display Interface: SVGA monitor port
  • Peripheral Interfaces: Keyboard and mouse connections
  • Status Indication: Three LEDs, per supplier documentation
  • Alternate Part Reference: UCVE08A, listed by Radwell
  • Operating System / Software Image: Verify from the installed unit and GE system records
  • Processor and Memory: Exact configuration should be confirmed against the board revision and applicable GE documentation
  • Installation: Mark VI controller rack; verify the intended slot and system configuration

Do not assume that general UCVE-family data applies to every IS215UCVEM08 assembly. Confirm processor, memory, firmware/software image, and interface details against the exact board revision before using them as acceptance criteria.

 

Global Sourcing & Live-Test SOP

For a used or surplus GE IS215UCVEM08, visual condition is only the first screening step. Controller hardware must be evaluated against the intended Mark VI configuration.

1. Inbound Verification

  • Photograph the complete GE nameplate and all board markings.
  • Confirm the exact part number.
  • Record serial number, revision, and assembly identifiers.
  • Inspect VME edge connectors, faceplate, ports, and mounting points.
  • Check for corrosion, contamination, heat discoloration, or evidence of repair.
  • Inspect the Ethernet and serial connectors for bent or damaged contacts.
  • Confirm whether any battery, memory media, or accessories are included.
  • Compare the board with the customer’s original controller.

2. Configuration and Compatibility Review

  • Confirm that the installed system is GE Mark VI.
  • Verify the required UCVE controller configuration and approved replacement part.
  • Check the installed software image and controller configuration records.
  • Confirm the intended rack slot and VME interface requirements.
  • Verify Ethernet addressing and serial-port usage from the machine documentation.
  • Do not treat UCVE08A or another UCVE variant as an automatic substitute without documented compatibility confirmation.

3. Controlled Power-Up and Functional Testing

Testing should be performed by qualified personnel using an appropriate GE-compatible test arrangement.

  • Inspect the board and connectors before applying power.
  • Confirm the approved rack and power arrangement.
  • Check startup behavior and available status indications.
  • Verify Ethernet and serial interfaces using a suitable test setup.
  • Confirm service-monitor output where applicable.
  • Check controller diagnostics and software-image status.
  • Record test conditions, observed behavior, and any fault indications.

Do not connect the controller to an operating turbine simply to establish whether it boots. Validate it in an appropriate test environment before field installation.

4. Extended Run and Diagnostics

Where a suitable test setup is available, perform an extended powered run appropriate to the controller and intended application.

Monitor:

  • Startup consistency
  • Controller diagnostic status
  • Ethernet and serial communication
  • Unexpected resets
  • Software-image or configuration faults
  • Abnormal heating
  • Connector and VME backplane integrity

Record test duration, board revision, software/configuration information, and observed results. Do not claim a complete functional test unless the test scope supports that statement.

5. Final Preparation

  • Record the exact model, revision, and serial number.
  • Photograph the board before packaging.
  • Preserve available diagnostic and test records.
  • Use ESD-safe packaging.
  • Protect the VME edge connector and faceplate from impact.
  • Clearly disclose whether the unit is new surplus, used, refurbished, tested, or untested.
  • Identify whether a software image, battery, or other configuration-dependent item is included.

 

Field Engineer’s Pitfall Guide

❗ A matching controller model does not guarantee a matching software environment

The ‘s suitability depends on the installed Mark VI configuration and controller software. Confirm the required software image and configuration before commissioning a replacement. A board that boots may still be unsuitable for the original application.

❗ Verify UCVE08A and related part-number references

Radwell lists UCVE08A as an alternate reference for . That cross-reference is a useful sourcing clue, not proof that every UCVE08A-marked assembly is interchangeable in every Mark VI application. Confirm the complete part number and approved replacement path.

❗ Do not confuse a service interface with a process-control interface

The SVGA and keyboard/mouse connections are service-oriented interfaces. They should not be represented as additional process-control communication ports. Confirm the function of each interface from the applicable GE documentation before connecting external equipment.

 

Intent-Driven FAQ

What is the GE ?

The is a GE Mark VI UCVE controller module used in Speedtronic turbine-control applications. Supplier references describe it as a single-slot controller and PC control module.

What communication ports does the have?

Supplier documentation lists one Ethernet port and two RS-232C serial ports, along with an SVGA service-monitor port and keyboard/mouse connections. Confirm the physical interface arrangement on the actual board.

Is the a PLC I/O module?

No. It is a controller/PC control module, not a conventional analog or digital I/O card. Its role is associated with Mark VI control processing.

Is interchangeable with ?

Radwell lists as an alternate reference. However, interchangeability should be confirmed against the exact hardware revision, software image, and installed Mark VI configuration before substitution.

Is the hot-swappable?

Do not assume it is hot-swappable. Treat replacement as a controlled maintenance operation under the site’s approved procedure. Follow GE and plant-specific instructions for controller isolation, removal, configuration, and commissioning.

Is the GE obsolete?

Radwell identifies the as discontinued by the manufacturer. It may still be available through surplus and industrial replacement-part channels, but stock, condition, and warranty terms vary by supplier.

What should I verify before purchasing?

Confirm the full part number, board revision, physical condition, software/configuration status, included accessories, and test status. Request clear photographs of the nameplate, faceplate, and connectors. For a production turbine, verify the replacement against the installed Mark VI configuration before ordering.

 

Bottom Line for Buyers

The is a legacy Mark VI UCVE controller module used in GE Speedtronic turbine-control applications. Its sourcing value depends on exact hardware identification, compatible software/configuration, and verified operating condition.

Before purchasing, request clear nameplate and board photographs, confirm the complete part number and revision, and establish whether the controller has been functionally tested. Do not treat a seller’s broad UCVE-family description as proof of system compatibility.

Business Card