Description
National Instruments SCXI-1104C | 32-Channel Analog Input Core Category
Dynamic Product Introduction
Field engineers understand how quickly automated testing stalls when high-level analog monitoring channels experience severe electrical noise or overvoltage attenuation failures. Honestly, trying to convert a high-density industrial voltage testing rack to modern C-Series hardware mid-project introduces massive re-cabling expenses, software framework rewrites, and extended downtime that test facility managers simply cannot afford. The National Instruments SCXI-1104C resolves this operational bottleneck by serving as a direct drop-in multiplexer replacement that preserves existing SCXI chassis slot configurations, wiring harnesses, and NI-DAQmx tasks.
Engineered specifically for medium-to-high voltage signals and dynamic acoustic/vibration raw voltage monitoring, this SCXI-1104C module features 32 differential channels equipped with individual 10 kHz low-pass filters to suppress high-frequency noise while maintaining signal fidelity. In industrial power monitoring, battery stack validation, and automotive test stands, replacing a degraded module with a bench-tested SCXI-1104C restores low-noise signal conditioning and high-accuracy channel scanning instantly—provided you pair it with a compatible high-voltage terminal block.

SCXI-1104C
Key Technical Specifications
- Input Channels: 32 differential analog input channels
- Maximum Input Voltage Range: ±42V peak (incorporates internal 10:1 precision voltage divider)
- Filter Cutoff Frequency: 10 kHz 2-pole low-pass Butterworth filter per channel
- Attenuation & Gain: Fixed attenuation of 0.1 (10:1 divider ratio); effective unity processing
- Isolation Rating: 250 V RMS working isolation (bank-to-earth ground and backplane bus)
- Multiplexing Architecture: High-speed analog bus output multiplexed into a single host DAQ channel
- Terminal Block Compatibility: SCXI-1300, SCXI-1308, SCXI-1327 (High Voltage)
- Power Requirements: Powered directly from SCXI chassis backplane (+5 VDC and ±15 VDC power rails)
- Operating Temperature Window: 0°C to +50°C ambient operational environment
Global Sourcing & Live-Test SOP (Transparency Core)
Sourcing discontinued or secondary-market NI DAQ hardware demands a strict zero-trust quality verification methodology. Inbound shipments of the SCXI-1104C undergo thorough customs documentation audits, serial number checks, and microscopic pin inspections to detect bent backplane DIN connectors, trace swelling, or heat-stressed passive components.
Once logged into inventory, every SCXI-1104C module transitions directly to our specialized DAQ diagnostic test rig. Technicians seat the card into an SCXI-1000 chassis paired with an SCXI-1300 terminal block and a PXI/PCI DAQ controller. We execute a 24-hour thermal soak while scanning all 32 channels with precision DC/AC voltage calibrators up to ±42V. Frequency response curves at the 10 kHz cutoff point, divider attenuation accuracy, and backplane multiplexing timing are fully verified before sealing the SCXI-1104C in anti-static ESD packaging prior to dispatch.
The Field Engineer’s Pitfall Guide
❗ Exceeding the ±42V Input Limit: Applying raw industrial voltages above the ±42V peak limit (e.g., direct 120 VAC line power) will blow the internal precision divider resistor network and permanently damage front-end multiplexer ICs.
❗ Mismatched Cutoff Frequency Expectations: Mistaking the SCXI-1104C (which features a 10 kHz filter for dynamic signals) for the standard SCXI-1104 (which features a 2 Hz filter for static DC signals) will allow unwanted 50/60 Hz power-line ripple into your measurement pipeline.
❗ Hot-Plugging Module into an Energized Chassis: Inserting or unseating the SCXI-1104C while the SCXI chassis backplane is energized can induce voltage spikes that corrupt onboard module EEPROM settings or disrupt active DAQmx driver sessions.
Intent-Driven FAQ
Will I need to rewrite my NI-DAQmx measurement code when replacing an SCXI-1104C module? No, because the SCXI-1104C contains an onboard EEPROM, NI-DAQmx automatically detects the module in its assigned chassis slot and maintains existing channel scaling parameters.
What is the main difference between the SCXI-1104 and the SCXI-1104C? The standard SCXI-1104 has a 2 Hz low-pass filter intended for low-speed DC voltage measurements, whereas the SCXI-1104C features a 10 kHz low-pass filter designed for higher-speed dynamic signal acquisition.
Are surplus National Instruments SCXI-1104C modules supplied in original factory packaging? Inventory conditions range from brand-new old stock (NOS) in original NI boxes to certified pre-owned surplus. Regardless of outer packaging condition, every SCXI-1104C module undergoes a complete 32-channel bench calibration and burn-in test before dispatch.
What causes unexpected scaling errors on channels connected to the SCXI-1104C? Scaling errors typically occur when software tasks fail to account for the internal 10:1 attenuation factor, or when using an uncalibrated custom terminal block with external resistor networks.
What warranty coverage applies to a replacement SCXI-1104C module? Our secondary-market and surplus National Instruments SCXI-1104C modules include a comprehensive 12-month operational warranty covering attenuation accuracy, filter response, multiplexing logic, and backplane bus stability under standard operating conditions.