Description
S30361-NA Kollmorgen | Replacement S300 Motion Controller | Fast Ship
Dynamic Product Introduction
Higher-torque automated axes requiring rapid dynamic response and heavy continuous load capacity rely on digital servo amplifiers capable of delivering clean, high-bandwidth current loops. The Kollmorgen S30361-NA serves as a compact, high-output digital servo amplifier designed for the S300 drive platform. Sourcing an exact-spec S30361-NA drive ensures complete drop-in physical alignment, exact terminal block pinouts, and seamless parameter upload without needing cabinet panel modifications or PLC motion profile rewrites.
Engineered for space-constrained electrical cabinets, packaging machinery, semiconductor equipment, and high-speed CNC rotary axes, the Kollmorgen S30361-NA doubles the continuous current rating of 1.5 A units up to 3.0 A RMS continuous (9.0 A RMS peak). The “NA” variant provides standard base I/O interfaces, accepting analog ±10 V velocity/torque commands, master encoder follower signals, or step/direction pulse streams. For motion control engineers and maintenance technicians servicing legacy Kollmorgen drive panels, deploying a fully load-tested replacement drive guarantees long-term axis stability and smooth motor performance.

S30361-NA
Key Technical Specifications
- Model Identification: Kollmorgen S30361-NA
- Drive Platform: S300 Series Compact Digital Servo Drives
- Input Power Rating: 110 V AC to 230 V AC Single-Phase (110–230V nominal, 47–63 Hz)
- Continuous Output Current: 3.0 A RMS per phase
- Peak Output Current: 9.0 A RMS (3-second peak acceleration duration)
- Interface Configuration: NA (Standard Base I/O – Analog ±10V, Step/Direction, Encoder Emulation)
- Motor Feedback Support: Resolver, Smart Feedback Device (SFD), EnDAT / Hiperface Absolute Encoders, Incremental Encoders
- Protection Features: Overvoltage, Undervoltage, Output Short Circuit (phase-to-phase / phase-to-ground), Motor Over-Temperature, Drive Thermal I²t Limiting
- Operating Temperature Range: 0°C to +45°C (32°F to +113°F)
Global Sourcing & Live-Test SOP (Transparency Core)
To guarantee 100% out-of-the-box performance prior to site installation, every reconditioned or factory-surplus Kollmorgen S300 servo drive undergoes a strict 5-stage physical and electrical diagnostic testing protocol before dispatch:
- Inbound Visual & Component Verification: Microscopic check of power and control terminal connectors, inspection of internal DC bus electrolytic capacitors for ESR degradation, heatsink cleanliness check, and validation of model designation S30361-NA.
- Power Stage & DC Bus Test: Single-phase AC power is applied to measure internal DC bus voltage generation and confirm soft-start inrush current limiter operation (Verification: 320 V DC bus nominal generated under 230 V AC input).
- Live Servo Loop & Dynamometer Test: The drive is coupled to a Kollmorgen AKM servomotor on a load bench, executing high-speed analog ±10 V and step/direction motion trajectories (Verification: Smooth current regulation across 100% rated continuous 3.0 A and peak 9.0 A load cycles).
- Environmental Thermal Burn-In: The unit undergoes an 18-hour continuous burn-in cycle at 40°C inside an environmental chamber while running continuous thermal load profiles.
- Final Prep: Motor power and feedback terminals receive anti-corrosion spray treatment, drive parameters are reset to baseline factory defaults, and the unit is packaged inside static-shielded ESD protective packaging.
The Field Engineer’s Pitfall Guide
Stored High Voltage DC Bus Hazard
Hazardous DC bus voltages (up to 400 V DC) remain present across internal drive capacitors for several minutes after AC input power is disconnected. Always verify the front-panel DC Bus LED is fully extinguished and test DC bus terminals with a multimeter before touching wiring.
❗ Confusing S30361-NA (3A Continuous) with S30301-NA (1.5A Continuous): Substituting an S30301 unit where an S30361 is required will cause premature I²t thermal tripping during continuous heavy acceleration cycles due to lower continuous current limits.
❗ Un-grounded Motor Shielding & Feedback Noise: Running motor power wires without a 360-degree shield clamp secured directly to the drive grounding bracket allows high-frequency PWM switching noise to couple onto resolver or encoder feedback cables, triggering false feedback fault trips.
❗ Inadequate Vertical Cabinet Clearance: Mounting S300 drives without specified vertical airflow space (minimum 75 mm above and below the drive) restricts natural convection across the integrated heatsink, causing premature thermal cutouts under high duty cycles. —In field deployments, I’ve seen an automated indexing station trip repeatedly simply because drives were installed tight against wire ducting without proper thermal spacing.
Intent-Driven FAQ
What does the “NA” suffix indicate on the Kollmorgen S30361-NA drive?
The “NA” suffix designates the standard base I/O hardware version without optional fieldbus expansions (such as CANopen or EtherCAT cards), accepting standard analog ±10 V, step/direction, and master encoder signals.
What is the continuous and peak output current rating of the S30361-NA?
The S30361-NA provides 3.0 A RMS continuous output current per phase and up to 9.0 A RMS peak output current for rapid acceleration phases.
How do I check drive status or active fault codes?
Observe the front-panel status display (Verification: A solid or blinking code indicates operational status or specific fault conditions, such as F01 for Overvoltage, F02 for Undervoltage, or F04 for Drive Over-Temperature).
Can the S30361-NA operate on 110 V AC single-phase input power?
Yes. The power stage is rated for single-phase operation across 110 V AC to 230 V AC nominal operating ranges.
What standard warranty applies to reconditioned or factory-sealed surplus units?
All reconditioned and factory-sealed surplus units carry a comprehensive 1-year replacement warranty covering power stage transistors, control input logic, and current loop regulation accuracy.