Sale!

ICS Triplex T8110B | Trusted TMR Processor Module SIL 3

Original price was: ¥999.00.Current price is: ¥888.00.

ICS Triplex T8110B | Trusted TMR Processor Module SIL 3

  • Model: ICS Triplex T8110B (Rockwell Automation / ICS Triplex Trusted TMR Processor)
  • Brand: ICS Triplex / Rockwell Automation
  • Series: Trusted Triple Modular Redundant (TMR) Safety System
  • Core Function: Fault-tolerant Triple Modular Redundant (TMR) main processor module executing deterministic IEC 61131-3 safety logic, 2oo3 hardware voting, and high-speed Internal Module Bus (IMB) control for SIL 3 safety instrumented systems.
  • Product Type: Triple Modular Redundant (TMR) Safety Processor Module
  • Key Specs: Triple-wide processor form factor (3 independent processor slices A, B, C), 24V DC backplane supply (20–32V DC range, 45 W typical / 65 W max), IEC 61508 SIL 3 certified, hot-swappable active/standby failover, front diagnostic LED matrix and keyswitch.
  • Status: Mature / Surplus OEM Safety Hardware Available
Category:

Description

ICS Triplex T8110B | Trusted TMR Processor Module SIL 3

 

Product Introduction

When an offshore oil and gas Emergency Shutdown (ESD) controller, refinery burner management system, or high-integrity pressure protection loop suffers a processor slice fault, standard dual-redundant PLCs cannot isolate single-channel hardware failures without risking process interruption or ambiguity. The ICS Triplex T8110B is not a conventional single-CPU PLC processor or general-purpose industrial controller; it is a triple-wide Triple Modular Redundant (TMR) safety processor engineered specifically for the Rockwell Automation / ICS Triplex Trusted platform. Slotted directly into the dedicated processor bay of a T8100 Trusted controller chassis, this model houses three independent, synchronized processor slices (Slices A, B, and C) behind a single front bezel.

Executing continuous two-out-of-three (2oo3) hardware voting across internal memory, clock synchronization, and backplane bus transactions, the ICS Triplex T8110B detects and masks any single-slice hardware error within microseconds without interrupting safety execution. When paired with a second T8110B in the standby processor slot, this model supports hot-standby failover and live online replacement—though your mileage may vary depending on Trusted Toolset firmware release compatibility, processor interface adapter (T813X) configuration, and cabinet cooling clearance. Installing a verified surplus ICS Triplex T8110B restores certified SIL 3 processing availability without re-validating application safety logic.

T8110B

T8110B

Key Technical Specifications

  • Manufacturer Part Number: T8110B (ICS Triplex / Rockwell Automation)
  • Safety Certification Rating: IEC 61508 SIL 3, TUV Certified for Safety Instrumented Systems (SIS)
  • Redundancy Architecture: Triple Modular Redundant (TMR) with 3 independent microprocessor slices (A, B, C) and 2oo3 hardware voting
  • Chassis Compatibility: Mounts in the triple-wide Processor Slot (Logic Slot 0 — Active or Standby) of the T8100 Trusted Controller Chassis
  • Backplane Communication: Triple-redundant Internal Module Bus (IMB) master interface managing local and expanded I/O chassis
  • External Interface Compatibility: Connects via rear Processor Interface Adapter (T813X series) for Ethernet, RS-232/RS-485 serial, and peer-to-peer links
  • Power Consumption & Supply: Powered via 24V DC chassis backplane (20V to 32V DC operating range); approx. 45 W typical / 65 W maximum consumption
  • Front Panel Controls & Diagnostics: 3-position security keyswitch (Run / Program / Stop), front RS-232 diagnostic port, and independent status/fault LED arrays for Slices A, B, and C
  • Hot-Swap Capability: Supports online replacement in dual-processor (Active/Standby) configurations without shutting down the process
  • Operating Temperature Window: 0°C to +60°C (+32°F to +140°F), 10% to 95% non-condensing relative humidity

 

Application Scenarios & Pain Points

Offshore Emergency Shutdown (ESD) & Fire and Gas Systems: Upstream platforms and FPSO vessels require SIL 3 safety controllers capable of surviving component faults without triggering costly spurious plant shutdowns. Installing the ICS Triplex T8110B executes 2oo3 hardware voting across three internal processor slices, maintaining uninterrupted safety monitoring even if one slice faults.

With vs. Without Hot-Standby Dual TMR Processors: Single-processor installations require scheduling a full process outage whenever firmware maintenance or hardware replacement is needed. With a dual Active/Standby pair inside a T8100 chassis, technicians can swap a faulted module live while the standby unit assumes control seamlessly.

Drop-In Replacement for Trusted Release 3.x Safety Racks: Migrating a certified Trusted safety application to a different PLC family requires full HAZOP re-verification and loop re-testing. Deploying an exact OEM ICS Triplex T8110B preserves validated IEC 61131-3 safety programs, rear T813X interface adapters, and field termination assemblies.

 

QA & Live Testing SOP (Trust Signal)

Every ICS Triplex T8110B TMR processor module in our warehouse undergoes thorough electrical, triple-slice synchronization, and backplane verification before shipment. Our safety-system technicians inspect the triple-wide housing, front security keyswitch, ejector latches, and rear high-density backplane connectors under magnification for mechanical wear, and verify internal power isolation on a Fluke precision multimeter.

Following static bench checks, the processor is installed into an energized T8100 Trusted test chassis populated with diagnostic I/O modules and a rear T813X interface adapter. We power up the rack at 24V DC, verify simultaneous boot-up and clock synchronization across all three processor slices (Slices A, B, and C), and confirm healthy green status indicators across the front LED matrix. We establish communication via the Trusted Toolset engineering software, test program download/readback, and verify Internal Module Bus (IMB) I/O scanning and Active/Standby failover behavior. Once fault-free TMR operation is proven, the backplane pins are shielded, the module is wrapped in heavy anti-static ESD protection, and packed in custom high-density foam.

 

Field Engineer’s Pitfall Guide

❗ Firmware Revision Alignment in Dual-Processor Racks: When installing an ICS Triplex T8110B as a Standby partner alongside an existing Active processor, both modules must run matching Trusted system firmware revisions (e.g., Release 3.6.x or 3.7.x). Mismatched firmware versions prevent automatic synchronization and keep the newly inserted processor from entering Standby-Ready state.

❗ Front Security Keyswitch Position & Write Protection: The physical 3-position keyswitch on the front bezel of this model governs program download and online modification permissions (Run, Program, Stop). Always confirm the keyswitch is turned to the authorized position required by your site’s Management of Change (MOC) procedure before attempting application downloads, and return it to Run afterward to lock out unauthorized changes.

❗ Rear Processor Interface Adapter (T813X) Seating & Grounding: External Ethernet and serial host communications route through the rear T813X Processor Interface Adapter mounted behind Slot 0 on the T8100 chassis. Before sliding the fully home and engaging the top/bottom locking latches, verify that the rear adapter screws are tight and its backplane pins are clean.

 

Intent-Driven FAQ

Q: Why is the ICS Triplex T8110B three slots wide? A: Because it is a Triple Modular Redundant (TMR) processor containing three completely independent hardware processor slices (Slices A, B, and C) that execute safety logic in parallel and vote 2oo3 on every operation.

Q: Can the T8110B be replaced online without shutting down the safety system? A: Yes, provided the T8100 chassis is configured with dual-redundant processors (Active and Standby); the healthy processor maintains continuous control while the faulted module is hot-swapped.

Q: Which chassis is required for the ICS Triplex T8110B processor? A: It mounts exclusively in the dedicated triple-wide processor bay (Logic Slot 0 — Active or Standby) of the ICS Triplex Trusted Controller Chassis.

Q: What safety integrity level is this processor certified for? A: The ICS Triplex T8110B is TUV-certified for use in Safety Instrumented Systems (SIS) up to IEC 61508 SIL 3.

Q: Are these ICS Triplex T8110B processor modules genuine OEM surplus units? A: Yes. We stock authentic original OEM ICS Triplex / Rockwell Automation hardware complete with factory serial labels, clean front keyswitches, and inspected backplane connectors.

Q: What warranty applies to this Trusted TMR processor? A: All new surplus ICS Triplex T8110B modules ship backed by a full 1-year replacement warranty covering electrical functionality and triple-slice synchronization reliability.

Business Card