Description
Rexroth R911268888 | Indramat HVR02.2-045-300-N
Dynamic Product Introduction
Automation maintenance engineers managing high-throughput automotive transfer lines, multi-axis printing presses, or large CNC machining centers know how disruptive a central DC bus failure can be. When a master power supply module experiences main bridge diode failure, bus over-voltage, or internal cooling fan lockup, restoring central DC power across all connected drive axes without modifying cabinet wiring or busbar configurations is a top priority.
The Bosch Rexroth Indramat HVR02.2-045-300-N (R911268888) acts as the central power unit for DIAX04 drive groups. It converts three-phase AC line power (380 to 480 V AC) into a tightly regulated 750 V DC bus. Unlike unregulated supplies, the HVR series features line-regenerative capabilities, feeding braking energy from high-inertia motors back into the factory AC grid to maximize energy efficiency. Featuring integrated bleeder protection, extensive status diagnostics, and seamless integration with Indramat HDS/HDD drive modules, the R911268888 provides stable, noise-immune power delivery under continuous heavy-duty servo operations.

R911268888
Key Technical Specifications
- Input Line Voltage: 3-phase 380 to 480 V AC (±10%, 50/60 Hz)
- Regulated DC Bus Voltage: 750 V DC (continuous voltage regulation)
- Continuous Power Rating: 45 kW
- Peak Power Output: Up to 135 kW (short-duration overload rating)
- Regenerative Functionality: Mains regeneration (returns braking kinetic energy back to 3-phase AC grid)
- Bleeder Resistor Rating: Onboard peak bleeder resistor for transient dissipation
- Control Voltage Input: 24 V DC external control voltage feed
- Cooling Method: Internal forced-air cooling fan assembly
- Enclosure Class: IP20 industrial enclosure (designed for control cabinet mounting)
- System Compatibility: DIAX04 drives (HDS, HDD series) and Indramat AC main/servo motors
Global Sourcing & Live-Test SOP (Transparency Core)
Sourcing replacement high-voltage industrial power supplies requires strict electrical and thermal verification to guarantee safe DC bus regulation and regeneration stability.
Inbound Verification & Traceability
- Paperwork Audit: Verification of serial numbers, material number R911268888, and full model code HVR02.2-045-300-N against Bosch Rexroth / Indramat production records.
- Physical Inspection: Detailed check of high-voltage DC busbar terminals, 3-phase AC input lug blocks, internal electrolytic capacitor banks (checking for bulging or electrolyte leakage), fan assembly blades, and diagnostic ribbon connectors.
Live Cabinet Simulation & Diagnostics
- Soft-Charge & Pre-Charge Verification: Powered via 400 V AC 3-phase mains to verify soft-charge relay operation and DC bus pre-charging sequencing.
- 750 V DC Bus Stability Check: Monitoring the output DC bus under variable line supply inputs to confirm steady 750 V DC regulation within ±1% limits.
- Regenerative Energy Simulation: Interfaced with a test servo motor rig undergoing forced deceleration cycles to confirm power feedback back into the AC line and verify bleeder activation thresholds.
- 24-Hour Load & Burn-In Run: Module undergoes a 24-hour thermal chamber test under continuous full-load current draw (45 kW simulation) to confirm cooling fan efficiency and power semiconductor thermal stability.
Final Prep
- Busbar & Terminal Prep: Cleaning edge contacts and installing protective terminal shrouds.
- ESD & Heavy-Duty Packaging: Unit is sealed in heavy-duty anti-static barrier film with moisture absorption packs before mounting into custom shock-absorbing wood/cardboard freight crates.
High-Voltage DC Electrical Hazard
The HVR02.2-045-300-N generates a high-voltage 750 V DC bus. Always disconnect the 3-phase AC mains supply and wait at least 5 minutes before touching any terminals or busbars. Verify with a calibrated DC voltmeter that the DC bus voltage across terminals L+ and L- has discharged below 50 V DC prior to performing any maintenance work.
The Field Engineer’s Pitfall Guide
- ❗ Connecting Without Line Reactor / Commutating Choke: The HVR02.2-045-300-N requires a dedicated external line reactor (commutation choke, such as NFD/KD series) installed in line with the 3-phase AC mains input. Running the HVR unit without the specified line choke will cause excessive line harmonic distortion, overheating of the input bridge, and immediate over-current faulting.
- ❗ DC Busbar Polarity Reversal: When linking the HVR supply to downstream DIAX04 drive modules (HDS/HDD), ensure that the L+ and L- busbars are installed with correct polarity alignment. Reversing DC bus connections will permanently destroy the input IGBT stages of all connected drive modules upon power-up.
- ❗ Control Power vs. Main Power Sequencing: 24 V DC control power must be present to energize internal protection and monitoring circuits before or simultaneously with the main 3-phase AC supply. Energizing the 3-phase AC line without control power can prevent the pre-charge circuit from operating properly, resulting in blown input fuses.
Intent-Driven FAQ
Will swapping out a damaged R911268888 require software or parameter re-programming?
No. The HVR02.2-045-300-N is a hardware-based power supply module and does not store drive parameter files or axis firmware. As long as the replacement unit matches the exact model code (HVR02.2-045-300-N), it acts as a direct plug-and-play unit for your DIAX04 system.
How do I troubleshoot a DC Bus Overvoltage fault (F2x/F8x error codes)?
DC bus overvoltage during motor deceleration usually indicates a failure in the regenerative line-feedback circuit, an open internal bleeder resistor, or a blown external line fuse on the AC mains side that prevents power from returning to the grid.
Can the HVR02.2-045-300-N be used in place of an HVE series power supply?
No. HVE series modules are unregulated power supplies (outputting approximately 1.35 times line voltage, ~530–600 V DC) without mains regeneration. The HVR series provides regulated 750 V DC with full regeneration. Replacing an HVE with an HVR requires verifying drive compatibility and installing the correct line reactor setup.
What is the purpose of the internal cooling fan assembly on the HVR?
The internal cooling fans dissipate heat generated by the main bridge rectifiers, IGBT inverter modules, and internal bleeder resistors. If a fan fails or becomes clogged with cabinet dust, the module will trip on thermal overload.
What warranty coverage comes with replacement units?
All verified Rexroth Indramat R911268888 / HVR02.2-045-300-N power supply modules include a standard 12-month full-replacement warranty covering power stage rectifiers, 750 V DC voltage regulation, and internal cooling fan systems.
If you need help checking line reactor part numbers, verifying DC busbar installation procedures, or troubleshooting fault diagnostic codes on your HVR02.2-045-300-N setup, let me know your current cabinet layout and I can guide you through the setup steps.