Sale!

Comat Releco R-S108V01-16-24VDC-C10-1 | Interface Relay Rack | In-Stock

Original price was: ¥999.00.Current price is: ¥888.00.

Comat Releco R-S108V01-16-24VDC-C10-1 | Interface Relay Rack | In-Stock

  • Exact Model: Comat Releco R-S108V01-16-24VDC-C10-1
  • OEM Brand: Comat Releco Group
  • System Series: R-S Series Industrial Interface Relay Modules
  • Core Function: Converts 24 V DC PLC I/O controller signals into 16 isolated high-capacity switching relay outputs for industrial actuators, solenoids, and motor starters.
  • Module Type: 16-Channel Plug-In Relay Interface Sub-Assembly Block
  • Defining Specs: 24 V DC coil actuation voltage, 16x C10-series plug-in relay sockets, integrated protection diodes, LED status indication per channel, 250 V AC / 10 A contact rating.
Category:

Description

Comat Releco R-S108V01-16-24VDC-C10-1 | Interface Relay Rack | In-Stock

 

Dynamic Product Introduction

Interfacing high-density PLC digital output modules with heavy inductive loads requires rugged isolation to prevent back-EMF spikes from destroying expensive controller outputs. The Comat Releco R-S108V01-16-24VDC-C10-1 serves as a high-integrity 16-channel relay interface block designed to sit between logic-level control circuits and field-level equipment. Sourcing an exact-spec R-S108V01-16-24VDC-C10-1 module eliminates cabinet rewiring and ensures full mechanical and pinout alignment with existing control panel DIN-rail layouts.

Engineered with individual plug-in C10-series power relays, the Comat Releco R-S108V01-16-24VDC-C10-1 provides high channel density along with easy field maintenance. Each channel incorporates a reverse-polarity flywheel diode across the 24 V DC coil input to suppress switching transients, alongside individual LED indicators for fast visual troubleshooting during machine setup. For control system engineers and plant technicians maintaining legacy automated assembly lines, deploying this fully tested interface module ensures continuous system uptime and reliable output isolation.

R-S108V01-16-24VDC-C10-1

R-S108V01-16-24VDC-C10-1

Key Technical Specifications

  • Model Identification: Comat Releco R-S108V01-16-24VDC-C10-1
  • Module Capacity: 16 Plug-In Relay Channels (Accepts C10-A10 / C10-series relays)
  • Nominal Coil Input Voltage: 24 V DC (19.2 V DC to 28.8 V DC operational range)
  • Contact Configuration (per channel): SPDT (1 Changeover / 1c)
  • Maximum Switching Voltage: 250 V AC / 125 V DC
  • Maximum Continuous Contact Current: 10 A per channel (2.5 kVA AC switching capacity)
  • Status Indication: Individual green LED indicators per channel
  • Coil Protection: Integrated flywheel / freewheeling diodes across all 24 V DC coils
  • Isolation Rating: 4000 V RMS coil-to-contact dielectric isolation
  • Mounting Type: Standard 35 mm DIN-rail mounting base

 

Global Sourcing & Live-Test SOP (Transparency Core)

To guarantee zero-defect performance prior to field installation, every reconditioned or factory-surplus relay module undergoes a comprehensive multi-point testing protocol before dispatch:

  • Inbound Verification: Visual inspection of terminal screw thread integrity, PCB solder trace health, backplane trace isolation, and verification of original Comat Releco model serial markings.
  • Coil & Contact Resistance Testing: Each of the 16 relay socket channels is tested for coil resistance (nominal 742 Ω for 24 V DC C10 coils) and initial contact resistance across both NO and NC terminals.
  • Full-Load Switching Test: A precision electrical load is applied to cycle all 16 channels simultaneously at 24 V DC, measuring actuation pick-up/drop-out times and verifying status LED illumination.
  • Environmental Thermal Burn-In: The unit undergoes an 18-hour continuous burn-in cycle under active 24 V DC coil energization at 50°C inside an environmental chamber.
  • Final Prep: Terminal block screws are set to baseline positions, socket locking clips are verified intact, and the module is packaged inside static-shielding ESD packaging with fresh moisture-absorbing desiccants.

 

The Field Engineer’s Pitfall Guide

High-Voltage Switching & Back-EMF Warning

Always disconnect the main 24 V DC logic supply and high-voltage AC load lines before removing or seating individual C10 plug-in relays within the R-S108V01-16-24VDC-C10-1 socket assembly.

❗ Inductive AC Load Arc Suppression: While the module features internal DC coil suppression diodes, switching heavy AC inductive loads (such as large motor contactor coils) directly at the relay output terminals requires external RC snubbers across the contacts to prevent contact welding over time.

❗ Coil Supply Polarity Sensitivity: Connecting 24 V DC auxiliary input leads with reversed polarity across the terminal block will short-circuit the internal flywheel diodes, blowing upstream PLC output fuses or damaging channel drive transistors.

❗ Over-Torquing Terminal Screw Clamps: Tightening field wiring terminal screws past recommended torque limits can crack the internal PCB mounting pads beneath the socket rail. —In field deployments, I’ve seen technicians lose an entire afternoon troubleshooting intermittent channel drops caused by a fractured trace under an over-torqued input terminal block.

 

Intent-Driven FAQ

What plug-in relay models are compatible with the R-S108V01-16-24VDC-C10-1 base?

The unit is designed to accept standard Comat Releco C10-series miniature plug-in relays (such as C10-A10X/DC24V or C10-A10BX/AD24V) with SPDT 10 A contact ratings.

Can individual relay channels be replaced without removing the entire base module from the DIN rail?

Yes. The C10-series relays feature plug-in pin configurations and integrated retaining clips, allowing field replacement of single faulted channels without disturbing cabinet wiring.

How do I troubleshoot a channel where the LED illuminates but the field load fails to energize?

Measure AC/DC voltage directly across the Output Common and NO terminal pins while the channel is active (Verification: If 24 V DC coil voltage is present and the LED lights up, but contact resistance reads infinite ohms, the internal relay contact is pitted or burned out and requires relay replacement).

Is the Comat Releco R-S108V01-16-24VDC-C10-1 suitable for high-frequency switching operations?

Mechanical relays within this assembly have a typical mechanical life of >10 million operations, but for high-frequency PWM or rapid cycling (>1 Hz), solid-state output modules should be used to prevent contact fatigue.

What standard warranty is included with reconditioned or surplus modules?

All reconditioned and factory-sealed units include a comprehensive 1-year replacement warranty covering socket pin contact, PCB trace integrity, and coil protection circuits.

Business Card