Sale!

Kollmorgen S70602-PBNANA | Digital Servo Drive 6A PROFIBUS DP STO

Original price was: ¥999.00.Current price is: ¥888.00.

Kollmorgen S70602-PBNANA | Digital Servo Drive 6A PROFIBUS DP STO

  • Exact Model: S70602-PBNANA
  • OEM Brand: Kollmorgen / Danaher Motion
  • System Series: S700 Digital Servo Drive Series
  • Core Function: Delivers closed-loop velocity, position, and torque control for synchronous servo motors via integrated PROFIBUS DP fieldbus messaging.
  • Module Type: Single-Axis Digital Servo Amplifier Module
  • Defining Specs: 6 Arms continuous output current, 208V to 480V 3-phase AC input voltage, Option Slot 1 populated with PROFIBUS DP expansion card (PB).
Category:

Description

Kollmorgen S70602-PBNANA | Digital Servo Drive 6A PROFIBUS DP STO

 

Dynamic Product Introduction

Few technical issues halt a high-throughput packaging, printing, or metal-forming line faster than an unprovoked fieldbus disconnect on a critical servo axis. When an aging drive starts dropping cyclic PROFIBUS telegrams or throwing latching power stage faults under dynamic load, sourcing a direct hardware replacement like the Kollmorgen S70602-PBNANA becomes an urgent field priority. Operating within the S700 platform, this digital servo amplifier processes high-density power delivery without consuming excessive panel depth.

The S70602-PBNANA replaces legacy analog speed controllers by combining a fast digital position loop, active cogging compensation, and multi-protocol feedback decoding into a single unit. With its Option Slot 1 factory-configured for PROFIBUS DP communications and onboard Safe Torque Off (STO) hardware enabled, it integrates directly into Siemens-centric or legacy PLC networks while maintaining strict machinery safety compliance.

S70602-PBNANA

S70602-PBNANA

Key Technical Specifications

The operational specifications below detail the power stage capability, control interfaces, and hardware ratings for the S70602-PBNANA digital drive:

  • Continuous Rated Output Current: 6 Arms
  • Peak Output Current: 12 Arms to 18 Arms dynamically scaled
  • AC Mains Input Voltage: 3x 208V AC (-10%) to 3x 480V AC (+10%), 50/60 Hz
  • Nominal DC Bus Voltage: 290V DC to 675V DC
  • Auxiliary Logic Voltage: 24V DC (±15%) via X3 terminal block
  • Apparent Output Power: 4.5 kVA rated capacity
  • Safety Rating: Integrated Safe Torque Off (STO), Single Channel, SIL2 / PL d compliant
  • Option Slot 1 Configuration: PROFIBUS DP Interface Card installed (PB)
  • Option Slots 2 & 3: Unpopulated (NA / NA)
  • Encoder & Feedback Interfaces: Resolver, EnDat 2.1/2.2, HIPERFACE, Sine/Cosine, BiSS, Incremental ROD
  • Setup & Diagnostic Ports: RS232 serial connection via 9-pin D-Sub (X6) using DriveGUI software
  • Mechanical Enclosure: Cabinet panel mounting with integrated rear aluminum heatsink

 

Global Sourcing & Live-Test SOP (Transparency Core)

Procuring replacement hardware like the S70602-PBNANA requires detailed quality control testing to ensure surplus or shelf-stock inventory functions flawlessly upon installation.

Inbound Verification

  • Paperwork Tracing: Every incoming S70602-PBNANA is cross-referenced against original factory shipment logs and OEM serial number registries to prevent gray-market or counterfeit units from entering supply channels.
  • Enclosure & Board Inspection: Metal housing covers, circuit trace paths, screw terminal blocks, and internal bus capacitors are visually inspected for physical damage, thermal degradation, or chemical contamination.

Live Simulation

  • Test Rig Powering: The unit is mounted to an authentic industrial rack backplane and powered up using isolated 24V DC logic power alongside a 3-phase 400V AC mains feed.
  • Closed-Loop Motor Testing: Connected to a matched Kollmorgen rotary servo motor utilizing a high-resolution encoder/resolver feedback cable.

Diagnostics

  • Load Profile Execution: Running multi-axis motion profiles inside the DriveGUI software suite verifies velocity loop stability and dynamic torque response under acceleration.
  • Fieldbus Handshake Validation: PROFIBUS DP cyclic process data exchange (PPO types) is verified against a master controller while monitoring bus traffic for frame errors.
  • Thermal Burn-in Run: The drive undergoes a continuous 24-hour heat test under 85% rated current load (5.1 Arms) inside an environmental test chamber to ensure thermal dissipation components remain stable.

Final Prep

  • Parameter Reset & Firmware Synchronization: Memory registers are reset to factory defaults, parameter files are archived, and the S70602-PBNANA is updated to the targeted customer firmware release.
  • ESD & Moisture-Proof Packaging: Sealed within a static-shielding ESD enclosure containing fresh desiccant packs before being packed into custom-molded protective foam packaging.

 

The Field Engineer’s Pitfall Guide

Swapping an S70602-PBNANA during an emergency machine shutdown presents specific integration hurdles. Pay close attention to these real-world failure scenarios:

  • ❗ PROFIBUS Station Address & Baud Rate Mismatches: Unlike Ethernet-based drives that auto-negotiate network parameters, the S70602-PBNANA relies on specific station address settings stored in internal memory or configured via rotary switches. Replacing a unit without matching the exact PROFIBUS node address and GSD configuration file in the master PLC will leave the drive in a permanent communication timeout state. I’ve seen engineering teams lose an entire shift assuming the PLC would automatically push down network node parameters to a factory-fresh unit.
  • ❗ Missing PROFIBUS Bus Termination: The PROFIBUS DP network requires physical 220-ohm termination resistors at the first and last physical nodes on the segment. When swapping out an end-of-line S70602-PBNANA drive, failing to switch the DB9 connector’s termination resistor to ON will introduce signal reflections that crash the entire fieldbus network loop.
  • ❗ Safe Torque Off (STO) Enabling Interlocks: The S70602-PBNANA features single-channel STO hardware on connector X4. If your control system does not utilize safety relay loops, forgetting to jumper the 24V DC logic supply directly to the STO input pin prevents the internal PWM power stage from firing, locking the drive in a hardware enable fault condition.

 

Intent-Driven FAQ

Q: Will installing a replacement S70602-PBNANA automatically overwrite my PROFIBUS node settings? A: No, a factory-fresh S70602-PBNANA boots up with default parameter values and a default PROFIBUS station address. You must set the correct node address via DriveGUI software over the X6 serial interface or via front keypad controls before reconnecting the drive to an active PROFIBUS network segment.

Q: What does the “PBNANA” suffix indicate on the S70602-PBNANA model code? A: The “PBNANA” suffix defines the hardware option card layout. “PB” indicates that Option Slot 1 is factory-populated with a PROFIBUS DP communication card, while the subsequent “NA” designations show that Option Slots 2 and 3 remain open and unpopulated.

Q: Can I operate the main power stage of an S70602-PBNANA on a single-phase 230V AC line for shop testing? A: No, the S70602-PBNANA is engineered specifically for 3-phase AC line input (208V to 480V AC). Supplying power across single-phase terminals will cause severe DC bus voltage ripple under motor load and trigger an immediate phase-loss protection trip.

Q: Is it safe to connect or disconnect the motor feedback cable while the 24V DC logic power is active on the S70602-PBNANA? A: Never disconnect the feedback cable on connector X1 or X2 while 24V DC logic power is applied to the unit. Hot-unplugging encoder lines can permanently damage the sensitive line driver components inside the S70602-PBNANA or corrupt absolute multi-turn position registers.

Q: How do I backup parameter sets from a failing S70602-PBNANA before removing it from the cabinet? A: Connect a PC running Kollmorgen DriveGUI software to the 9-pin RS232 port (X6) on the front of the drive. Establish a serial connection, choose the Parameter Save function to save the .prm file locally, and load that exact file onto the replacement S70602-PBNANA once physically mounted.

Business Card