ABB 3BSE018741R15 | RVVP-TPE Industrial Shielded Cable | In-Stock

Original price was: ¥999.00.Current price is: ¥888.00.

ABB 3BSE018741R15 | RVVP-TPE Industrial Shielded Cable | In-Stock

  • Exact Model: ABB RVVP-TPE (Part Number: 3BSE018741R15)
  • OEM Brand: ABB (Process Automation / Advant Master / S800 I/O Division)
  • System Series: Advant Controller & S800 I/O Fieldbus Infrastructure
  • Core Function: Functions as a 15-meter pre-fabricated, heavy-duty shielded system cable assembly designed for high-integrity serial data transmission between DCS processor racks and remote I/O bases.
  • Module Type: Pre-Assembled Shielded Industrial System Cable (15 Meters)
  • Defining Specs: 15 m length (“R15” suffix), RVVP copper-braided shield construction, TPE (Thermoplastic Elastomer) jacket, oil/UV/chemical resistance, heavy-duty industrial multi-pin connector termination.
Category:

Description

ABB 3BSE018741R15 | RVVP-TPE Industrial Shielded Cable | In-Stock

 

Dynamic Product Introduction

Ensuring zero-packet-loss serial communications across distributed control systems (DCS) requires interconnecting cables built to withstand severe electromagnetic interference and environmental stress. The ABB RVVP-TPE 3BSE018741R15 provides a 15-meter factory-terminated system cable engineered specifically for ABB Advant Controller and S800 I/O network backplanes. Sourcing an exact-part-number replacement guarantees correct signal impedance, pinout continuity, and shielding integrity without requiring field soldering or manual connector assembly.

Designed for harsh industrial automation environments, the ABB RVVP-TPE 3BSE018741R15 features a durable Thermoplastic Elastomer (TPE) outer jacket combined with high-density tinned copper braided shielding (RVVP). This construction provides exceptional flexibility, resistance to ambient oil mist and aggressive chemicals, and superior protection against common-mode noise generated by nearby VFDs or high-voltage switchgear. For plant automation engineers and control technicians maintaining critical process loops, deploying a fully tested factory cable assembly prevents intermittent communication drops and simplifies cabinet interconnection.

RVVP-TPE 3BSE018741R15

RVVP-TPE 3BSE018741R15

Key Technical Specifications

  • Model Identification: ABB RVVP-TPE (Part Number: 3BSE018741R15)
  • Cable Length: 15 Meters (49.2 Feet)
  • Cable Construction: RVVP (PVC/TPE Insulated, Tinned Copper Shielded, Flexible Stranded Conductors)
  • Jacket Material: TPE (Thermoplastic Elastomer – High Chemical & Oil Resistance)
  • Shielding: Tinned Copper Wire Braid + Aluminum Foil Outer Wrap (>85% Shield Coverage)
  • Connector Configuration: Factory molded multi-pin industrial D-sub or backplane connectors (per ABB S800/Advant spec)
  • Operating Voltage Rating: 300 V RMS
  • Operating Temperature Range: -30°C to +80°C (-22°F to +176°F)
  • Minimum Bend Radius: Fixed installation: 6x Cable Diameter; Flexible installation: 12x Cable Diameter

 

Global Sourcing & Live-Test SOP (Transparency Core)

To ensure factory-grade reliability prior to dispatch, every reconditioned or new-surplus cable assembly undergoes a rigorous 5-stage verification protocol:

  • Inbound Physical Inspection: Visual verification of part number 3BSE018741R15 markings, outer TPE jacket inspection for cuts or thermal degradation, and mechanical lock-latch check on connectors.
  • Automated Continuity & Wire-Map Testing: Every individual conductor pin is tested via automated cable analyzer to confirm 100% pinout mapping against ABB OEM schematics (Verification: Zero open pins, shorted conductors, or cross-wired pairs detected).
  • High-Potential (Hi-Pot) Dielectric Insulation Test: 1000 V DC is applied between adjacent conductor cores and outer braid shield for 60 seconds to verify insulation resistance exceeds 100 MΩ.
  • Signal Integrity Loopback Test: The cable is integrated into an active ABB test rack running high-baud-rate serial traffic for 6 hours to verify packet loss counts under continuous bend cycles.
  • Final Prep: Connector pins are cleaned with electrical contact restorer, protective anti-dust caps are fitted onto both connector ends, and the cable is coiled, wire-tied, and sealed inside anti-static packaging.

 

The Field Engineer’s Pitfall Guide

Cable Shield Grounding & Bend Radius Warning

Always connect cable shield drain wires to designated single-point control panel earth terminals. Never exceed the minimum bend radius (12x outer diameter) during installation, as sharp bends can sever internal shield braiding or cause conductor impedance mismatches.

❗ Exceeding Pulling Tension Limits: Yanking the 15-meter cable through tight conduit or cable trays can stretch internal copper conductors or tear the outer TPE jacket. Always use proper cable pulling grips and lubricants when routing long runs.

❗ Routing Adjacent to High-Voltage Power Lines: Running the 3BSE018741R15 parallel to 480 V motor feeds or VFD output cabling without physical partition channels can induce electromagnetic noise despite the RVVP shield. Maintain a minimum 300 mm (12 in) separation from power wiring.

❗ Unsecured Connector Latches in High-Vibration Enclosures: Continuous machine vibration can cause loose connector retaining screws to back out over time. —In field deployments, I’ve seen a compressor station drop offline simply because an un-torqued connector screw loosened, causing an intermittent RX/TX drop on the primary bus.

 

Intent-Driven FAQ

What does the “R15” suffix signify in the ABB part number 3BSE018741R15?

The “R15” suffix designates the specific factory cable length of 15 meters. Shorter variants (e.g., R05 for 5 meters or R10 for 10 meters) follow the same base part number structure.

What is the benefit of a TPE jacket over standard PVC for industrial cable runs?

Thermoplastic Elastomer (TPE) provides superior flexibility, higher mechanical tear resistance, and enhanced chemical protection against industrial oils, coolants, and UV exposure compared to standard PVC.

How do I test if an installed cable has an internal shield break?

Use a digital multimeter set to low ohms to measure resistance between the metal connector shell at End A and the metal connector shell at End B (Verification: Resistance should read less than 1.0 Ω; higher readings indicate damaged outer braid shielding).

Can this cable assembly be field-repaired or shortened if damaged?

While conductors can technically be re-soldered, field-splicing invalidates factory shielding effectiveness and signal impedance specifications. Replacing damaged runs with a factory-tested assembly is strongly recommended.

What warranty coverage is included with surplus or reconditioned units?

All reconditioned and factory-sealed surplus units carry a comprehensive 1-year replacement warranty covering conductor continuity, pinout mapping, and dielectric insulation stability.